Communication terminal number and signal details (RS-485)
RS-485
Connection to the RS-485 port of the host computer (master)
The cable and termination resistor (s) must be provided by the customer.
Terminal
No.
Signal name
Symbol
25 Signal
ground SG
26 Send/Receive
data
T/R
(A)
27 Send/Receive
data
T/R
(B)
Screw size: M3
×
7 (with 5.8
×
5.8 square washer)
Recommended tightening torque:
0.4
N
・
m (4 kgf
・
cm)
Recommended solderless terminals:
Manufactured
by
J.S.T MFG CO., LTD.
Circular terminal with isolation V1.25-MS3
(M3 screw, width 5.9 mm, hole diameter 3.2 mm)
*R: Termination resistors (Example: 120
1/2 W)
If communication errors occur frequently due to the
operation environment or the communication distance,
connect termination resistors.
Host computer (Master)
RS-485
Paired wire
Shielded twisted
pair wire
PG500 (Slave)
*R
*R
25
T/R (B)
T/R (A) 26
27
SG
T/R (B)
T/R (A)
SG
(
)
(
)
PG500 (Slave)
25
T/R (B)
T/R (A) 26
27
SG
(
)
(
)
(
)
(
)
Maximum connections:
Up to 31 instruments
To prevent electric shock or instrument failure, turn off the power before
connecting or disconnecting the instrument and peripheral equipment.
WARNING
!
Communication terminals
PG500 rear view
27
26
25
Содержание PG500
Страница 1: ...IMR02F04 E1 PG500 Communication Instruction Manual RKC INSTRUMENT INC Pressure Indicator...
Страница 68: ...62 IMR02F04 E1 MEMO...
Страница 69: ...The first edition JUN 2014 IMQ00...