36 | Installing and Configuring the SteelHead
Configuring in-path SteelHeads
If you are using the SteelHead with a terminal server, the terminal server must use hardware flow
control for the port connected to the SteelHead.
We recommend that you connect the console port to a device that logs output. Even though this is
not a requirement, it can help you to identify problems with the system.
3. Log in as administrator user (
admin
) and enter the default password (
password
). The configuration
wizard automatically starts after you have entered the login and default password. After you have
established a connection, you configure the SteelHead using the configuration wizard.
4. If you have an SCC appliance installed in your network to manage multiple SteelHeads, you can use
it to automatically configure them:
Do you want to auto-configure using a SCC? no
If you answer
yes
, you are prompted for the SCC host name or IP address. The host name or IP
address is used to contact the SCC. The default value is riverbedcmc. If you enter
no
, the wizard
continues.
Note:
If you mistakenly answer
yes
, to return to the wizard from the CLI, enter the
configuration jump-start
command from configuration mode. For detailed information, see the
“To restart the configuration wizard” on
5. To start the configuration wizard, enter
yes
at the system prompt. Press
Enter
to enter the default
value; press
?
for help; press
Ctrl-B
to go back to the previous step.
6. Complete the configuration wizard steps on the client-side and the server-side SteelHeads as
described in this table.
Wizard prompt
Description
Step 1: Host name?
Enter the host name for the SteelHead.
Step 2: Use DHCP on the
primary interface?
You are given the option to enable the DHCP to automatically assign an IP
address to the primary interface for the SteelHead.
We recommend that you don’t set DHCP.
The default value is no.
Step 3: Primary IP address?
Enter the IP address for the SteelHead.
Step 4: Netmask?
Enter the netmask address.
Step 5: Default gateway?
Enter the default gateway for the SteelHead.
Step 6: Primary DNS server?
Enter the primary DNS server IP address.
Step 7: Domain name?
Enter the domain name for the network where the SteelHead is to reside.
If you set a domain name, you can enter host names in the system without
the domain name.
Step 8: Admin password?
We strongly recommend that you change the default administrator password
at this time. The password must be a minimum of six characters.
The default administrator password is password.
Содержание SteelHead 5080
Страница 10: ...10 Welcome Contacting Riverbed...
Страница 16: ...16 Riverbed Software Licenses Upgrades and Image Signing Software upgrades and image signing...
Страница 60: ...60 Troubleshooting Network integration checklist...
Страница 90: ...90 CX x70 Desktop Appliance Specifications CX 570 and CX 770 specifications...
Страница 94: ...94 CX x55 Appliance Specifications CX 255 specifications...