8 Troubleshooting
Ritta l crimping machine R8-I
We reserve the right to make technical m odifications
27
EN
Fig. 18:
Inserting blades
◼
Place each blade-pair together so that the angled edges (marked red in fig. 18)
point outwards.
◼
Place both blade-pairs in the retainer.
◼
Refasten the cover.
◼
Fasten both cams so that they are located in position "0".
◼
Perform an insulation stripping test (see section 5.4 "Performing the insulation
stripping test").
8.4
Replacing fuses
◼
Ensure that the automatic machine is switched off.
◼
Remove the mains connector.
Fig. 19:
Opening the fuse box
◼
Lever the fuse box (fig. 19, item 1) with a flat screwdriver from the mains filter
unit.
◼
Replace both fuses with new ones (2 x T2AH250V).
◼
Insert the fuse box back into the mains filter unit.
1
1
1