8 Troubleshooting
Ritta l crimping machine R8-I
We reserve the right to make technical m odifications
25
EN
◼
To replace the filter, unscrew the condensate container (fig. 16, item 2) and
screw out the filter (fig. 16, item 3).
◼
Insert a new filter and retighten the condensate container.
8
Troubleshooting
Note:
If a malfunction cannot be rectified with the measures described
here, contact Rittal Service.
8.1
Malfunction table
Malfunction
Possible cause
Recommended measure
The automatic machine
cannot be switched on.
The power supply is interrupted
◼
Check the mains cable and the mains connection.
◼
Check the fuses.
No start for inserted con-
ductor.
The start sensor (S1) is blocked by
stripped insulation scrap
◼
Open the front panel.
◼
Swivel the tool unit to the right.
◼
Pull the stranded wire fixing unit forwards.
◼
Remove the scrap from the insulation stripping unit.
◼
Return all components to their initial position.
Conductor inserted incorrectly
◼
Insert the conductor straight.
The wire is stripped only of
its insulation but not
crimped.
Operating mode "Only insulation
stripping" is set
◼
Change the operating mode to Standard (setting "0" in
Menu 3).
The settings on the automatic ma-
chine do not match the associated
sleeve
◼
Check whether the settings for sleeve cross-section
match the associated sleeve.
No wire end ferrule reel inserted
◼
Insert a wire end ferrule reel.
Increased rejects
Insulation stripping blades damaged
or installed incorrectly
◼
Check the seating of the insulation stripping blades (see
section 7.6 "Maintaining the insulation stripping unit").
◼
Correct the seating of the insulation stripping blades or
replace them (see section 8.3 "Replacing the insulation
stripping blade").
Stripped insulation scrap between the
tool unit and the right limit stop
◼
Remove the stripped insulation scrap.
The second sleeve is located in the
sleeve holding unit
◼
Remove the sleeve.
8.2
Wearing parts
Product
Model No.
Insulation stripping blade, titanium
4050.466