Heat Exchanger Thermistor
When measuring resistance always make sure the power supply to the unit is turned off and the
component being check is isolated from the P.C. board.
1. Measure resistance of
Heat Exchanger Thermistor on the P.C. board at Connector H)
:
a. Connector “H” white wire pin #2 (turns black at P.C. board) & white wire pin #6.
Resistance Values
59 ˚F = 11.4 ~ 14K ohms
86 ˚F = 6.4 ~ 7.8K ohms
113 ˚F = 3.6 ~ 4.5K ohms
140˚F = 2.2 ~ 2.7K ohms
221 ˚F = 0.6 ~ 0.8K ohms