Enhancing Lives By Changing The Way Water Is Heated

SS

Service Soon Alert 

- 55

is a time-

based service indicator set during installation. See section “3.12 

Parameter Settings” in owner’s manual for additional details on setting and  
changing the 

55 

indicator.  

- 55

indicates that it is time for service. The heat exchanger should be flushed to 

prevent damage (refer to section “5.3 Flushing the Heat Exchanger” in owner’s    
manual for more information). 

Hard water must be treated to prevent scale  

build-up or damage to the heat exchanger.

- To reset the 

55

code, push the 

On/Off 

button on the temperature controller 5 times  

in 5 seconds.  

NO Code

Unit does not operate or post an error 

code when water flow is initiated. 

- Check/clean inlet water supply filter.
- Ensure the minimum activation water flow rate is met. 
- Ensure hot and cold water lines are not reversed / cross connected. 
- Ensure there is not a crossover / cross connection somewhere in the building  

plumbing or a plumbing fixture. 

- Check to ensure the water flow turbine spins freely. 
- Measure resistance of the water flow sensor.
- If the display is blank and clicking is coming from the unit, disconnect the water flow  

servo motor. If the display comes on, replace the water flow servo. 

SE

Cascade Diagnostic Display 

(Commercial units only)

-

With cascade connections on commercial units, the primary unit’s display will flash  

between “SE” and the selected set temperature when an error code is displayed on 
any secondary unit.

FF

Maintenance Indicator

- Placeholder in Diagnostic code history indicating that a service provider performed 

maintenance or service. Enter this code after performing service by pressing the 
UP, DOWN and ON/OFF button simultaneously.

Fault Codes 

Содержание Sensei N-Series

Страница 1: ...1 11 6 2018 2015 Rinnai America Corporation PROPRIETARY and CONFIDENTIAL Enhancing Lives By Changing The Way Water Is Heated Rinnai N Series Level III Service Presentation Version 01032018GW...

Страница 2: ...is necessary as a copper heat exchanger could become clogged by corrosion b Burner Why use stainless steel mesh To eliminate resonance noise in the event the burner is compromised or the flame become...

Страница 3: ...cedure allows you to confirm your settings with the controller s display e Gas Valve Why use a zero governor gas valve Rinnai switched to this valve system in order to satisfy the PVC 2 air exhaust ve...

Страница 4: ...inside heat exchanger as high as possible the WFSV was relocated g Pressure relief valve Why was the pressure relief valve moved When the WFSV was relocated there was a possibility pressure inside the...

Страница 5: ...roduct and burner maintenance l Maximum Flow Rate Allows for higher flow rates in warm ground water areas m Condense Drain Code Eliminated A blocked condense drain will post code 10 same as flue block...

Страница 6: ...6 11 6 2018 2015 Rinnai America Corporation PROPRIETARY and CONFIDENTIAL Enhancing Lives By Changing The Way Water Is Heated N Series Water Heaters External Model Internal Model...

Страница 7: ...8 0 GPM 6 1 GPM 4 4 GPM 92 RU160e REU N2530W US RU180i REU N2934FF US 15K 180K 0 4 GPM 9 0 GPM 6 9 GPM 4 9 GPM 92 RU180e REU N2934W US RU199i REU N3237FF US 15K 199K 0 4 GPM 9 8 GPM 7 7 GPM 5 5 GPM 9...

Страница 8: ...on Flow Rate approx Max Flow Rate 30 Rise Max Flow Rate 50 Rise Max Flow Rate 70 Rise Uniform Energy Factor UEF CU160i REU N2530FFC US 15K 160K 0 4 GPM 8 0 GPM 6 1 GPM 4 4 GPM 96 thermal Efficiency CU...

Страница 9: ...nai s listed and tested vent systems Electrical System MUST be properly sized for load at location Refer to the National Electrical Code for details Each unit requires 120 Volts AC 4 amp grounded circ...

Страница 10: ...orders Monday Friday from 8 a m to 8 p m EST Ship from 8 00 a m to 6 30 p m EST Online ordering Rinnai Parts Store 24 7 Warranty Department Available in office from 8 a m to 5 p m EST Monday Friday Te...

Страница 11: ...nied with replacement procedures 3 N Series Parameter Settings See Owner s Manual for complete details Some parameter settings will required adjustments especially those for higher set point temperatu...

Страница 12: ...ves By Changing The Way Water Is Heated Primary Service Tools For service troubleshooting and component replacement the following tools are needed 2 Phillips Head magnetic Small Phillips Head U Tube D...

Страница 13: ...To remove front cover press in on the plastic strip with your thumb at the red circles shown on the picture to the right Pull strip out away from the unit Under the plastic strip you will find four Ph...

Страница 14: ...Way Water Is Heated 1 Remove screw shown below to pull controller from unit 2 Unplug the 15 wire connector J on the P C board 3 To add additional remote controllers use the wiring harness provided wi...

Страница 15: ...15 11 6 2018 2015 Rinnai America Corporation PROPRIETARY and CONFIDENTIAL Enhancing Lives By Changing The Way Water Is Heated Flame Rod Electrode Sight Glass Plate Removal...

Страница 16: ...Remove 3 screws shown with red circles 2 Unplug yellow flame rod wire 3 Unplug black electrode cable and green wire to casing 4 Remove sight grass plate flame rods and electrode from unit 5 Before re...

Страница 17: ...17 11 6 2018 2015 Rinnai America Corporation PROPRIETARY and CONFIDENTIAL Enhancing Lives By Changing The Way Water Is Heated Heat Exchanger Thermistor Removal...

Страница 18: ...pulling retainer clip off thermistor Pull thermistor out of position Ensure O ring is intact and in good condition before reinstalling it Make sure the retainer clip is installed in the proper orienta...

Страница 19: ...19 11 6 2018 2015 Rinnai America Corporation PROPRIETARY and CONFIDENTIAL Enhancing Lives By Changing The Way Water Is Heated Outgoing Water Thermistor Removal...

Страница 20: ...e any hot water or water pressure remaining in the system 1 Remove the outgoing water temperature thermistor shown below with red arrow Remove Phillips head screw and pull thermistor out of position e...

Страница 21: ...21 11 6 2018 2015 Rinnai America Corporation PROPRIETARY and CONFIDENTIAL Enhancing Lives By Changing The Way Water Is Heated Bi metal Over Heat Switch...

Страница 22: ...cuit activates based on the temperature range listed below Bi metal switch automatically reset once the temperature drops below the activation point 1 Overheat switch located on the right side of the...

Страница 23: ...eat Exchanger bi metal opens at 230 and resets at 203 If the outlet thermistor detects 9 F over the temperature set point The heat exchanger bi metal will post a code 14 on the controller The flame wi...

Страница 24: ...24 11 6 2018 2015 Rinnai America Corporation PROPRIETARY and CONFIDENTIAL Enhancing Lives By Changing The Way Water Is Heated Gas Valve and Fan Motor Removal...

Страница 25: ...wer and gas 1 Unplug red fan motor connector 2 Unplug pink exhaust temperature thermistor connector 3 Unplug gas valve 8 pin connector 4 Unplug gas valve 2 pin connector 5 Unplug pink heat exchanger b...

Страница 26: ...Remove fan motor assembly from gas valve remove 4 screws from bottom of fan housing shown in red circles 2 Replace O ring between fan assembly and gas valve 1 Combustion Fan Gas Valve Removal Fan Exha...

Страница 27: ...and CONFIDENTIAL Enhancing Lives By Changing The Way Water Is Heated Heat Exchanger Assembly Which includes the air box burner Secondary Heat Exchanger The Sensei Heat Exchanger is made of 444 Stainl...

Страница 28: ...Unplug heat exchanger thermistor follow wire down to green connector 2 Unplug ceramic heater at green connector and unclip ceramic heater from secondary heat exchanger feed line 3 Unplug bi metal swi...

Страница 29: ...bled from system 1 Remove stainless steel clip stamped 18 28 on hot water outlet line Pull line loose from fitting 2 Remove stainless steel clip stamped 14 23 on bypass line Pull line loose from fitt...

Страница 30: ...e red circles 2 Remove 4 screws from the secondary heat exchanger bracket 3 Remove 1 screw from black plastic air box top center of water heater 4 Lift bottom of secondary heat exchanger out towards y...

Страница 31: ...emove caulking material at the four corners of the heat exchanger Make sure surface is clean flat to maintain airtightness Caulking material is not needed for replacement heat exchanger Burner gasket...

Страница 32: ...hanger fixing screw Replace secondary heat exchanger gasket Ensure surface is clean before installing new gasket Repace duct fixing screws 4 screws with white coating Replace O rings in water circuit...

Страница 33: ...33 11 6 2018 2015 Rinnai America Corporation PROPRIETARY and CONFIDENTIAL Enhancing Lives By Changing The Way Water Is Heated Air Box Removal...

Страница 34: ...America Corporation PROPRIETARY and CONFIDENTIAL Enhancing Lives By Changing The Way Water Is Heated Air Box Removal 1 Remove the 9 screws shown in red circles and pull the air box away from primary s...

Страница 35: ...35 11 6 2018 2015 Rinnai America Corporation PROPRIETARY and CONFIDENTIAL Enhancing Lives By Changing The Way Water Is Heated Primary Secondary Heat Exchanger Disassembly...

Страница 36: ...s By Changing The Way Water Is Heated 1 Remove 14 screws shown in red circles separate secondary primary heat exchangers see example to right Primary Secondary Heat Exchanger Disassembly Bottom view o...

Страница 37: ...37 11 6 2018 2015 Rinnai America Corporation PROPRIETARY and CONFIDENTIAL Enhancing Lives By Changing The Way Water Is Heated Burner Disassembly...

Страница 38: ...y Changing The Way Water Is Heated Burner Disassembly 1 Remove 8 screws shown in red circles pull burner plate and burner assembly from unit The burner right bottom fits in inside the burner plate pic...

Страница 39: ...39 11 6 2018 2015 Rinnai America Corporation PROPRIETARY and CONFIDENTIAL Enhancing Lives By Changing The Way Water Is Heated Water Flow Servo Valve Removal...

Страница 40: ...se outlet water line Pull copper line away from WFSV 2 Remove stainless steel clip stamped 10 17 holding PRV line in place Pull line loose from bypass valve 3 Unplug WFSV control valve seven wire conn...

Страница 41: ...41 11 6 2018 2015 Rinnai America Corporation PROPRIETARY and CONFIDENTIAL Enhancing Lives By Changing The Way Water Is Heated Bypass Valve Flow Turbine Removal...

Страница 42: ...etainers Pull water lines loose from bypass valve assembly 2 Unplug red three wire connector black yellow red wires 3 Unplug lite blue four wire connector red blue pink white wires 4 Remove 1 screw ho...

Страница 43: ...pliers and slide the turbine assembly out of the bypass valve To disassemble turbine remove end cap and impeller from the turbine housing Clean all components with running water and a soft brush and...

Страница 44: ...44 11 6 2018 2015 Rinnai America Corporation PROPRIETARY and CONFIDENTIAL Enhancing Lives By Changing The Way Water Is Heated Condensate Trap Removal...

Страница 45: ...ater Is Heated Condensate Trap Removal 1 Compress clamp and slide off drain pipe and condense trap connection 2 Unplug ceramic heater for condensate trap 3 Remove 2 screws holding condensate trap to t...

Страница 46: ...46 11 6 2018 2015 Rinnai America Corporation PROPRIETARY and CONFIDENTIAL Enhancing Lives By Changing The Way Water Is Heated P C Board Removal...

Страница 47: ...inet disconnect all wiring harness connections on board Take care not to stress the connections when unplugging them Press in on the latch to release each connector before unplugging it A small screw...

Страница 48: ...ay Water Is Heated Product Reassembly Re assemble in opposite order of disassembly All screws should be placed in the correct location DO NOT over tighten screws All wiring harness connections must be...

Страница 49: ...49 11 6 2018 2015 Rinnai America Corporation PROPRIETARY and CONFIDENTIAL Enhancing Lives By Changing The Way Water Is Heated Accessory Connections...

Страница 50: ...ng Harness Part 105000249 Optional Accessory Harnesses Connector Locations Cascade Communication harness IN Cascade Communication harness OUT Part REU EZC 2 is the wiring harness shown above This harn...

Страница 51: ...51 11 6 2018 2015 Rinnai America Corporation PROPRIETARY and CONFIDENTIAL Enhancing Lives By Changing The Way Water Is Heated Electrical Values and Fault Codes...

Страница 52: ...vent possible damage to plugs 3 Know your meter and how to set it for each type of measurement Always set meter to next highest value from range listed in troubleshooting sheets Ohms or resistance VAC...

Страница 53: ...America Corporation PROPRIETARY and CONFIDENTIAL Enhancing Lives By Changing The Way Water Is Heated Power Supply 1 Check for 120 V A C Power Supply to the water heater Plug CN1 a Connector A pin 1 wh...

Страница 54: ...Lives By Changing The Way Water Is Heated Power Supply Fuse When measuring resistance always make sure the power supply to the unit is turned off and the component being check is isolated from the P C...

Страница 55: ...ing Lives By Changing The Way Water Is Heated Pump Circuit Fuse When measuring resistance always make sure the power supply to the unit is turned off and the component being check is isolated from the...

Страница 56: ...itch When measuring resistance always make sure the power supply to the unit is turned off and the component being check is isolated from the P C board 1 Measure resistance and or voltage of the Overh...

Страница 57: ...oid Valve When measuring resistance always make sure the power supply to the unit is turned off and the component being check is isolated from the P C board 1 Measure resistance and or voltage of the...

Страница 58: ...ponent being check is isolated from the P C board Voltage readings will occur when fan motor is energized 1 Measure voltage of the Fan Motor on P C board at Connector D a Connector D red wire pin 4 bl...

Страница 59: ...off and the component being check is isolated from the P C board 1 Measure resistance of Outgoing Water Thermistor on P C board at Connector H a Connector H white wire pin 2 turns black at P C board...

Страница 60: ...being check is isolated from the P C board 1 Measure resistance of Inlet Water Thermistor on P C board at Connector H a Connector H white wire turns black at P C board pin 2 white wire pin 4 at red a...

Страница 61: ...ated from the P C board 1 Measure resistance or voltage of Water Flow Control Device WFSV on P C board at Connector D a Connector D red wire turns black at P C board pin 30 pink wire pin 20 44 52 at r...

Страница 62: ...nce always make sure the power supply to the unit is turned off and the component being check is isolated from the P C board 1 Measure resistance of Exhaust Temperature Thermistor on P C board at Conn...

Страница 63: ...make sure the power supply to the unit is turned off and the component being check is isolated from the P C board 1 Measure resistance of Heat Exchanger Thermistor on the P C board at Connector H a Co...

Страница 64: ...st be turned on to the appliance for this section of troubleshooting 1 Measure voltage of Water Flow Sensor on P C board at Connector H D on P C board a Connector D black wire pin 30 red wire pin 12 s...

Страница 65: ...tance always make sure the power supply to the unit is turned off and the component being check is isolated from the P C board 1 Measure voltage of Freeze Protection Thermistor on the P C board at Con...

Страница 66: ...l Valve When measuring resistance always make sure the power supply to the unit is turned off and the component being check is isolated from the P C board 1 Measure resistance of By Pass Flow Control...

Страница 67: ...Servo on the P C board at Connector D a Connector D Red wire pin 12 Black wire pin 30 at the P C board 12 14 VDC when 120 VAC is on feeding unit at black arrows b Connector D Brown wire pin 25 Black w...

Страница 68: ...Electrode When measuring resistance always make sure the power supply to the unit is turned off and the component being check is isolated from the P C board 1 Measure resistance or voltage of Igniter...

Страница 69: ...r supply to the unit is turned off and the component being check is isolated from the P C board 1 Measure voltage of Additional Remote Controller s on the P C board at Connector CN211 a Connector CN21...

Страница 70: ...ves By Changing The Way Water Is Heated Freeze Protection Heater Circuit Power must be turned on to the appliance for this section of troubleshooting 1 Check for 120 VAC to Freeze Protection Heater Ci...

Страница 71: ...71 11 6 2018 2015 Rinnai America Corporation PROPRIETARY and CONFIDENTIAL Enhancing Lives By Changing The Way Water Is Heated Maintenance Diagnostic Codes Diagram...

Страница 72: ...Way Water Is Heated Maintenance Diagnostic Codes Diagram 120 Volt Power Supply 10 amps 11 12 71 51 70 Defective PC board Color coding BK Black BR Brown R Red O Orange Y Yellow G Green B Blue PR Purple...

Страница 73: ...roducts should be less than 4 amps in units without a circulation pump built in or connected to the unit N Series Water Heaters requires 120 VAC 60 Hz 4 amp properly grounded circuit power source when...

Страница 74: ...ntrollers Connected Connected or not 1 Connected 2 Not connected 07 Water Flow Servo Position Position 0 Partially Open 1 Open 2 Closed 08 Inlet Water Temperature Deg Fahrenheit Calculated Inlet Water...

Страница 75: ...ons X1 000 gallons A2 Total water usage x1 000 000 gallons Total gallons X1 000 000 gallons C0 Total Calorie 1 Kcal min X1Kcal min C1 Total Calorie 1 000 Kcal min X1 000 Kcal min C2 Total Calorie 1 00...

Страница 76: ...all vent components for proper connections Ensure vent length is within limits Check fan for blockage and proper operation Verify high altitude parameter was properly set Ensure exhaust check valve b...

Страница 77: ...uri Confirm the appropriate orifice venturi is being used in the gas valve Replace fan 12 Flame Failure Check for obstructions in the flue outlet If the system is propane ensure the tank has adequate...

Страница 78: ...Safety shutdown outlet water temperature exceeded 203 F 95 C Check for restrictions in air flow around the vent terminal Check fan for proper operation Check for foreign materials in the combustion c...

Страница 79: ...Inlet Water Temperature Thermistor 52 Gas Valve Check flame rod wiring for loose broken or damaged components or connections Check gas solenoid wire harness for loose or damaged terminals Measure resi...

Страница 80: ...ure water flow servo valve did not fail in the closed position Ensure parameters are properly set for the type circulation mode being used Cross Over or dedicated mode See owner s manual for details 6...

Страница 81: ...clean inlet water supply filter Ensure the minimum activation water flow rate is met Ensure hot and cold water lines are not reversed cross connected Ensure there is not a crossover cross connection s...

Страница 82: ...82 11 6 2018 2015 Rinnai America Corporation PROPRIETARY and CONFIDENTIAL Enhancing Lives By Changing The Way Water Is Heated Warranty Maintenance...

Страница 83: ...rts and Components 5 Years 5 Years Reasonable Labor 1 Year 1 Year Notes The heat exchanger warranty will be 15 years or 12 000 operation hours whichever occurs first From date of purchase period of co...

Страница 84: ...ally thereafter Before removing the inlet filter ensure that the water supply has been turned off and all pressure in the hot water system has been drained off by opening a hot water tap to ensure no...

Страница 85: ...85 11 6 2018 2015 Rinnai America Corporation PROPRIETARY and CONFIDENTIAL Enhancing Lives By Changing The Way Water Is Heated Maintenance...

Страница 86: ...rate of 4 GPM 15 1 L min 10 Turn off the pump 11 Rinse the cleaning solution from the water heater by a Remove the free end of the drain hose H3 from the pail and place in a suitable drain b Close se...

Страница 87: ...of the structure a suitable drain pan MUST be installed under the appliances Rinnai recommends the use of water treatment in hard water areas Water heaters utilizing a circulation system will require...

Страница 88: ...88 11 6 2018 2015 Rinnai America Corporation PROPRIETARY and CONFIDENTIAL Enhancing Lives By Changing The Way Water Is Heated Gas Requirements...

Страница 89: ...will also occur with incorrect venting Installation may operate correctly until winter then furnace kicks on and gas demand increases Now gas system is determined to be undersized due to not taking in...

Страница 90: ...es of water column on Natural or 0 5 inches on Propane gas when using black iron piping with all gas appliances firing on high fire If using a gas piping other than black iron please refer to that man...

Страница 91: ...ng The Way Water Is Heated Gas Conversion Process 1 Disconnect the electrical power 2 Turn off the gas supply 3 Remove 4 screws securing the front panel remove of unit 4 Locate orifice cover plate on...

Страница 92: ...ng Figure 2 7 Install the new inner and outer gaskets on to the new orifice Figure 2 8 Install new orifice into housing Check the gas type displayed on the orifice Red Orifice is LPG Blue Orifice is N...

Страница 93: ...93 11 6 2018 2015 Rinnai America Corporation PROPRIETARY and CONFIDENTIAL Enhancing Lives By Changing The Way Water Is Heated Programming Parameter Settings...

Страница 94: ...0 610 m Installations over 2 001 ft require a parameter change These units can be installed in applications up to 10 200 ft Maximum Water Flow Rate the rate at which water flows through the water hea...

Страница 95: ...0 610 m Installations over 2 001 ft require a parameter change These units can be installed in applications up to 10 200 ft Maximum Water Flow Rate the rate at which water flows through the water hea...

Страница 96: ...es By Changing The Way Water Is Heated Adjusting Parameters 1 Locate the PC Board lower right side of unit 2 Locate the two push buttons A and B on the PC Board 3 Press the A button 4 Use the and down...

Страница 97: ...setting number is selected use the On Off button on the controller to change the selection for that setting number Example Display will change from 01A to 01b for Maximum Temperature setting as shown...

Страница 98: ...0 F Residential 185 F Commercial 02 High Altitude Level 0 0 2 000 ft 0 610M Level 1 2 001 ft 5 400ft 610m 1 646m Level 2 5 401ft 7 700ft 1 646m 2 347m Level 3 7 701ft 10 200ft 2 347m 3 109m 03 Service...

Страница 99: ...p temperature remains higher but also uses more energy Economy mode cycles the pump less often using less energy to maintain the circulation loop temperature 3 BMS Building Management System 4 Setting...

Страница 100: ...d temperature setting 01A or 01b 2 Press the On Off button to scroll through the available temperature settings 3 When the desired temperature setting appears in the display press the top push button...

Страница 101: ...Changing The Way Water Is Heated Adjust Altitude 1 Press and hold the top push button A on the PC Board for 1 second The display will initially indicate the active temperature setting 01A or 01b 2 Pr...

Страница 102: ...de setting 4 When the desired altitude setting appears in the display press the top push button A on the PC board for 1 second to save the setting and return the water heater to normal operation mode...

Страница 103: ...The Way Water Is Heated Adjust Maximum Flow Rate 1 Press and hold the top push button A on the PC Board for 1 second The display will initially indicate the active temperature setting 01A or 01b 2 Pre...

Страница 104: ...On Off button on the controller to scroll to the desired Maximum Flow Rate setting 4 When the desired altitude setting appears in the display press the top push button A on the PC Board for 1 second...

Страница 105: ...ng The Way Water Is Heated To Obtain Performance Data 1 Press and hold the Down button 2 While holding the Down button for 2 seconds press and hold the On Off button hold both buttons simultaneously 3...

Страница 106: ...tion 05 Fan Frequency Hz 06 Additional Controllers Connected See following information 07 Water Flow Servo Position 0 mid 1 Open 2 Closed 08 Inlet Temperature F 09 Fan Current x10 mA 10 Total Bath Fil...

Страница 107: ...Is Heated Performance Data Details CONTROLLER MODEL CONNECTED NOT CONNECTED MC 001 000 BC 010 000 BSC BSC2 100 200 QTY2 000 Performance Data 06 Additional Controllers Connected to Product CYCLE COUNT...

Страница 108: ...Pipe Direct Vent 2 units 65 65 4 PVC CPVC Dual Pipe Direct Vent 2 units 65 150 6 PVC CPVC Dual Pipe Direct Vent 2 units 65 150 PVC CPVC PP NON DIRECT COMMON VENT Room Air RESIDENTIAL 3 PVC CPVC Singl...

Страница 109: ...Air 3 Units 150 150 150 150 150 150 6 Vent Dual Pipe Direct Vent Single Pipe Room Air 4 Units 150 150 150 150 150 150 6 Vent Dual Pipe Direct Vent Single Pipe Room Air 5 Units 150 150 150 150 6 Vent D...

Страница 110: ...up to 24 water heaters can be electronically connected The cascade connection enables all connected water heaters to modulate operation and function as one single hot water source The connection will...

Страница 111: ...e Cascade Cable to the Cascade OUT accessory port on the first primary water heater s PC Board 2 Connect the other end of the Cascade cable to the Cascade IN accessory port on the next secondary water...

Страница 112: ...e in the standby mode Standby units will maintain operation with the water flow control valve in the Open position The standby units will be ready to fire when sufficient water flow is detected The re...

Страница 113: ...gs the display will be as shown below Primary Secondary 1 Secondary 2 Secondary 3 When the Primary unit is designated through parameter setting 08 the displays will show the set temperature Secondary...

Страница 114: ...IDENTIAL Enhancing Lives By Changing The Way Water Is Heated Servicing or Replacing a Cascading Unit While servicing or replacing a unit using Rinnai s cascade system you MUST isolate that unit from t...

Страница 115: ...RIETARY and CONFIDENTIAL Enhancing Lives By Changing The Way Water Is Heated Servicing or Replacing a Cascading Unit Once service or unit replacement is complete reconnect the cascade cables back to t...

Страница 116: ...116 11 6 2018 2015 Rinnai America Corporation PROPRIETARY and CONFIDENTIAL Enhancing Lives By Changing The Way Water Is Heated Voltage and Resistance Values...

Страница 117: ...black Less than 1 ohm or 11 13 VDC 4 Measure resistance and or voltage of the Main Gas Valve Solenoid Plug D7 a Connector D black wire pin 27 yellow wire pin 29 18 22 ohms or 11 13 VDC 5 Measure resi...

Страница 118: ...r D grey wire turns black before getting to board pin 30 orange wire pin 12 12 14 VDC 9 Measure resistance of Exhaust Temperature Thermistor Plug H3 a Connector H white wire pin 2 turns black before g...

Страница 119: ...Servo Plug D5 a Connector D Red wire pin 12 Black wire pin 30 at the P C board 12 14 VDC when 120 VAC b Connector D Brown wire pin 25 Black wire pin 30 at the P C board Less than 1 VDC c Connector D G...

Отзывы: