Enhancing Lives By Changing The Way Water Is Heated
j. Conversion Process:
- Simplified
–
Remove three screws on gas valve, change gas orifice and reset
gas type parameter. 8 kits available, each with venturi and water heater rating plate.
k. Inlet Air Filter:
- Filtered inlet air to reduce product and burner maintenance
l. Maximum Flow Rate:
- Allows for higher flow rates in warm ground water areas
m. Condense Drain Code Eliminated:
- A blocked condense drain will post code 10, same as flue block. Always check the
condense drain first before proceeding with troubleshooting the vent system.
n. Service Soon (55):
- This function replaces the LC function. It allows you to select a service schedule. Factory setting
is in the DISABLE position. Set to your selection at parameter 03.
Parameter 03b = 6 months
Parameter 03c = 1 yr.
Parameter 03d = 2 yrs.
Product Changes