Model
Designation
Full Model Number
Min
Btu’s
Max
Btu’s
Min
Activation
Flow Rate
(approx.)
Max Flow
Rate 30
°
Rise
Max Flow
Rate 50
°
Rise
Max Flow
Rate 70
⁰
Rise
Uniform
Energy
Factor
(UEF)
RU130i
REU-N2025FF-US
15K
130K
0.4 GPM
6.6 GPM
5.0 GPM
3.5 GPM
.91
RU130e
REU-N2025W-US
.92
RU160i
REU-N2530FF-US
15K
160K
0.4 GPM
8.0 GPM
6.1 GPM
4.4 GPM
.92
RU160e
REU-N2530W-US
RU180i
REU-N2934FF-US
15K
180K
0.4 GPM
9.0 GPM
6.9 GPM
4.9 GPM
.92
RU180e
REU-N2934W-US
RU199i
REU-N3237FF-US
15K
199K
0.4 GPM
9.8 GPM
7.7 GPM
5.5 GPM
.93
RU199e
REU-N3237W-US
.92
*RUR160i
REU-NP2530FF-US
15K
160K
0.4 GPM
8.0 GPM
6.1 GPM
4.4 GPM
.92
*RUR160e
REU-NP2530W-US
*RUR199i
REU-NP3237FF-US
15K
199K
0.4 GPM
9.8 GPM
7.7 GPM
5.5 GPM
.93
*RUR199e
REU-NP3237W-US
.92
*RUR residential models include an integrated circulation pump and a thermal bypass valve. The MC-195 or the
Control R system must be used (purchased separately) in order for the circulation pump to operate.
Residential Models