98
11/6/2018
© 2015 Rinnai America Corporation
PROPRIETARY and CONFIDENTIAL
Enhancing Lives By Changing The Way Water Is Heated
Parameter Setting Table
Setting
Number
Setting
Description
Selection
A
B
C
D
E
F
01
Maximum
Set
Temperature
120°F
–
Residential
140°F
–
Commercial
140°F
–
Residential
185°F
–
Commercial
02
High Altitude
Level 0
0 - 2,000 ft.
(0 - 610M)
Level 1
2,001 ft. - 5,400ft.
(610m - 1,646m)
Level 2
5,401ft. - 7,700ft.
(1,646m - 2,347m)
Level 3
7,701ft. - 10,200ft.
(2,347m - 3,109m)
03
Service Soon
1
Disable
0.5 Yr.
1 Yr.
2 Yr.
04
Recirculation
Settings
No Recirculation
Recirculation Modes
Dedicated Mode
Cross Over Mode
Long Loop
Short Loop
05
Recirculation
Mode
2
Economy
Comfort
06
Control Switch
BMS
3
AH
07
EZ Connect
2 Units
1 Unit
08
Cascade
4
Secondary
Primary