100
11/6/2018
© 2015 Rinnai America Corporation
PROPRIETARY and CONFIDENTIAL
Enhancing Lives By Changing The Way Water Is Heated
A
A
B
Adjust Maximum Temperature
1.
Press and hold the top push button (“A”) on the PC Board for 1 second. The display will indicate the
currently selected temperature setting (01A or 01b).
2.
Press the “On/Off” button to scroll through the available temperature settings.
3.
When the desired temperature setting appears in the display, press the top push button (“A”) on the PC
board for 1 second to save the setting and return the water heater to normal operation mode.
A
B
1
2
Setting
Maximum Temperature
01A
120°F (49°C) Factory Default (
Residential)
140°F (60°C) Factory Default (
Commercial
01b
140°F (60°C) (
Residential)
185°F (85°C) (
Commercial
A
B
3