Additional Controller(s)
When measuring resistance always make sure the power supply to the unit is turned off and the
component being check is isolated from the P.C. board
1. Measure voltage of
Additional Remote Controller(s) on the P.C. board at Connector CN211:
a. Connector “CN211” on the P.C. board check across terminals 1 & 3 for 10 ~ 13 VDC.
Note:
The activation flow rate for the N-Series Water Heaters is 0.4 gpm.
No need to make any adjustments when set above 120 degrees Fahrenheit.