Chapter 2 To Set the Vertical System
RIGOL
MSO8000 User Guide
2-5
of the screen. The following window is displayed. Tap the
icon at the
right side of the
Offset
input field to decrease or increase the offset. You can
also tap the
Offset
input field to input a specific value with the displayed
numeric keypad.
Channel Coupling
The undesired signals can be filtered out by setting the coupling mode. For example,
the signal under test is a square waveform with DC offset.
⚫
When the coupling mode is "DC": the DC and AC components of the signal under
test can both pass the channel.
⚫
When the coupling mode is "AC": the DC components of the signal under test
are blocked.
⚫
When the coupling mode is "GND", the DC and AC components of the signal
under test are both blocked.
Press
1
to open the setting menu of CH1. Then, press
Coupling
continuously or
rotate the multifunction knob
to select the desired
coupling mode (by default, it
is DC). The current coupling mode is displayed in the channel status label at the
bottom of the screen, as shown in the figure below. You can also enable the touch
screen, and then touch the CH1 setting menu to select the desired coupling mode.
DC AC GND
Note:
⚫
When the input impedance is set to "50 Ω
", the channel coupling is set to DC
coupling by force, and the
Coupling
menu is grayed out and cannot be
modified.
⚫
When the coupling mode is "AC", the input impedance is set to 1 M
Ω
by force,
and the
Impedance
menu is grayed out and cannot be modified.
Value Input Field Decrease Increase
Содержание MSO8000 Series
Страница 1: ...User Guide MSO8000 Series Digital Oscilloscope Mar 2021 RIGOL TECHNOLOGIES CO LTD...
Страница 2: ......
Страница 24: ......
Страница 72: ......
Страница 78: ......
Страница 148: ......
Страница 202: ......
Страница 208: ......
Страница 214: ......
Страница 248: ...RIGOL Chapter 12 Protocol Decoding 12 14 MSO8000 User Guide...
Страница 264: ...RIGOL Chapter 12 Protocol Decoding 12 30 MSO8000 User Guide Sync Error...
Страница 274: ...RIGOL Chapter 12 Protocol Decoding 12 40 MSO8000 User Guide TSS Sync Frame Frame ID PL HCRC CYC Data TCRC...
Страница 284: ......
Страница 290: ......
Страница 296: ......
Страница 302: ......
Страница 308: ......
Страница 360: ......
Страница 383: ...Chapter 21 Remote Control RIGOL MSO8000 User Guide 21 3 5 6 3 4...
Страница 394: ......