![Rigol MSO8000 Series Скачать руководство пользователя страница 194](http://html1.mh-extra.com/html/rigol/mso8000-series/mso8000-series_user-manual_1461151194.webp)
RIGOL
Chapter 6 Operations and Measurements
6-46
MSO8000 User Guide
⚫
Press
BY
, then rotate the multifunction knob
to adjust the vertical
position of Cursor B (Y cursor).
Enable the touch screen and tap
BY
, then the numeric keypad is
displayed. Set the vertical position of Cursor B (Y cursor). The vertical
axis indicates voltage, and the unit of its setting value is the same as
that of the vertical axis.
⚫
Press
AY BY
, then rotate the multifunction knob
to adjust the
vertical position of Cursor A and Cursor B (Y cursors) simultaneously.
The vertical spacing between Cursor A and Cursor B (Y cursors)
remains unchanged.
Note:
If one of the three items (
AX
,
BX
, and
AX BX
) or one of the three items
(
AY
,
BY
, and
AY BY
) is selected, you can press down the multifunction
knob
continuously to switch among the three items.
4.
Select Screen Region
⚫
When the delayed sweep function is disabled, press
More
, and "Main" is
automatically selected under
Region
and cannot be modified.
⚫
When the delayed sweep function is enabled, the screen is divided into two
regions: main time base and zoomed time base. Press
Region
continuously
to select "Main" or "Zoom".
➢
When "Main" is selected, the cursor is displayed in the main time base
region, and you can measure the parameters in the main time base
region.
➢
When "Zoom" is selected, the cursor is displayed in the zoomed time
base region, and you can measure the parameters in the zoomed time
base region.
5.
Set the Horizontal/Vertical Measurement Unit
⚫
When "X" is selected under
Select
, you can set the horizontal measurement
unit. When the source can be Math1-Math4, this menu is grayed out and
disabled.
Press
More
→
Hori. Unit
, and rotate the multifunction knob
to select
the horizontal measurement unit. Then press down the knob to select it. You
can also press
Hori. Unit
continuously or enable the touch screen to select
it. The available units include "s", "Hz", "Degree(°)", and "Percent(%)".
➢
s: measures the time value at X Cursor (taking the trigger position as
reference). The measurement results include AX, BX,
△
X, and 1/
△
X.
Wherein, AX, BX, and
△
X all indicate time, and 1/
△
X indicates
frequency.
➢
Hz: measures the frequency value at X Cursor (taking the trigger
position as reference). The measurement results include AX, BX,
△
X,
and 1/
△
X. Wherein, AX, BX, and
△
X all indicate frequency, and 1/
△
X
indicates time.
Содержание MSO8000 Series
Страница 1: ...User Guide MSO8000 Series Digital Oscilloscope Mar 2021 RIGOL TECHNOLOGIES CO LTD...
Страница 2: ......
Страница 24: ......
Страница 72: ......
Страница 78: ......
Страница 148: ......
Страница 202: ......
Страница 208: ......
Страница 214: ......
Страница 248: ...RIGOL Chapter 12 Protocol Decoding 12 14 MSO8000 User Guide...
Страница 264: ...RIGOL Chapter 12 Protocol Decoding 12 30 MSO8000 User Guide Sync Error...