them to the current pass/fail test function.
To Set the Output Form of the Test Results
Press
Option
to enter the "Option" menu. You can set what the oscilloscope will
execute when test results are detected according to your needs.
⚫
Set the output event and Aux output
➢
Press
Output Event
, and rotate the multifunction knob
to select "Fail"
or "Pass". Press down the knob to select it. You can also press
Output
Event
continuously to enable the touch screen to select it.
➢
Press
Aux Output
continuously to enable or disable the Aux output. If
enabled, press
Utility
→
System
, and then the
AUX Out
is automatically
set to "PassFail". When a successful or failed event is detected, a pulse will
be output from the rear-panel
[TRIG OUT]
connector. If the Aux output is
disabled, press
Utility
→
System
, and then the
AUX Out
is automatically
set to "TrigOut". The output of the rear-panel
[TRIG OUT]
connector is
irrelevant with the pass/fail test.
⚫
Set the output polarity and output pulse width
Press
Polarity
continuously to select "Positive" or "Negative". Then press
Pulse
,
rotate the multifunction knob
or use the pop-up numeric keypad to set the
pulse width. Its range is from 100 ns to 10 ms. By default, it is 1
μ
s.
⚫
Set the error action
Press
Err Action
, and rotate the multifunction knob
to set the operation
that the oscilloscope will execute once a failed test is detected. Press down the
knob to select it. You can also press
Err Action
continuously and press down
the multifunction knob
to select it. Also, you can enable the touch screen to
select it.
➢
Stop:
indicates stopping test when a pass/fail test event is found.
➢
Beeper:
indicates that the beeper sounds an alarm when a pass/fail test
event is found (irrelevant with the on/off status of the beeper).
➢
Screenshot:
performs the screenshot operation when a pass/fail test
event is found. If an external storage device is detected, the screenshot will
be saved to the external storage device directly. Otherwise, it will be saved
to the local disk.
Note:
If "Screenshot" is selected under
Err Action
, "Stop" action will be
executed forcibly. The test will be stopped automatically. After the
Screenshot operation is completed, the test will continue.
Содержание MSO8000 Series
Страница 1: ...User Guide MSO8000 Series Digital Oscilloscope Mar 2021 RIGOL TECHNOLOGIES CO LTD...
Страница 2: ......
Страница 24: ......
Страница 72: ......
Страница 78: ......
Страница 148: ......
Страница 202: ......
Страница 208: ......
Страница 214: ......
Страница 248: ...RIGOL Chapter 12 Protocol Decoding 12 14 MSO8000 User Guide...
Страница 264: ...RIGOL Chapter 12 Protocol Decoding 12 30 MSO8000 User Guide Sync Error...
Страница 274: ...RIGOL Chapter 12 Protocol Decoding 12 40 MSO8000 User Guide TSS Sync Frame Frame ID PL HCRC CYC Data TCRC...
Страница 284: ......
Страница 290: ......
Страница 296: ......
Страница 302: ......
Страница 308: ......
Страница 360: ......
Страница 383: ...Chapter 21 Remote Control RIGOL MSO8000 User Guide 21 3 5 6 3 4...
Страница 394: ......