RIGOL
Chapter 6 Operations and Measurements
6-24
MSO8000 User Guide
SourceA. Then press down the knob to select the channel. You can also press
SourceA
continuously or enable the touch screen to select the channel. The
available channels for SourceA are CH1-CH4 and Ref1-Ref10.
Note:
The source of Math2 can be CH1-CH4, Ref1-Ref10, or Math1; the source
of Math3 can be CH1-CH4, Ref1-Ref10, Math1, or Math2; the source of
Math4 can be CH1-CH4, Ref1-Ref10, Math1, Math2, or Math3; only the
channels that have been enabled currently can be selected.
⚫
Press
Offset
to set the vertical offset of the operation results. For setting
methods, refer to the descriptions in
". You can
also directly rotate
Wave Vertical
POSITION
or enable the touch screen
to adjust the vertical offset.
⚫
Press
Scale
to set the vertical scale of the operation results. For setting methods,
refer to the descriptions in
. You can also
directly rotate
Wave Vertical
SCALE
or enable the touch screen to adjust
the vertical scale.
⚫
Press
AutoSetting
to adjust the vertical scale and offset of the operation
results to an optimal value based on the current configuration, so as to better
observe.
⚫
Press
More
→
ωc
1
to set the lower limit frequency. For setting methods, refer
to descriptions in
.
⚫
Press
More
→
ωc
2
to set the upper limit frequency. For setting methods, refer
to descriptions in
.
Note:
The settable ranges of the upper and lower limit frequencies are related
to the Math sample rate (displayed at the bottom of the screen when the
Math function is enabled). The sample rate of the analog channel or the
changes of the memory depth can affect the Math sample rate.
⚫
Press
More
→
Invert
to enable or disable the inverted display function of the
waveform.
⚫
Press
More
→
Label
to set the label for math operation results. For details,
refer to descriptions in
.
⚫
Press
More
→
Color Grade
to enable or disable the color grade display of the
operation results. When enabled, different colors are displayed on the screen to
indicate the times of data acquisition or acquisition probability.
⚫
Press
More
→
Reset ColorGrade
to clear the color grade display and display
the color grade again.
Band Stop
Only allows the signals whose frequencies are lower than the current lower limit
frequency and higher than the current upper limit frequency to pass.
Press
Math
→
Math1
→
Operator
to select "BandStop":
Содержание MSO8000 Series
Страница 1: ...User Guide MSO8000 Series Digital Oscilloscope Mar 2021 RIGOL TECHNOLOGIES CO LTD...
Страница 2: ......
Страница 24: ......
Страница 72: ......
Страница 78: ......
Страница 148: ......
Страница 202: ......
Страница 208: ......
Страница 214: ......
Страница 248: ...RIGOL Chapter 12 Protocol Decoding 12 14 MSO8000 User Guide...
Страница 264: ...RIGOL Chapter 12 Protocol Decoding 12 30 MSO8000 User Guide Sync Error...
Страница 274: ...RIGOL Chapter 12 Protocol Decoding 12 40 MSO8000 User Guide TSS Sync Frame Frame ID PL HCRC CYC Data TCRC...
Страница 284: ......
Страница 290: ......
Страница 296: ......
Страница 302: ......
Страница 308: ......
Страница 360: ......
Страница 383: ...Chapter 21 Remote Control RIGOL MSO8000 User Guide 21 3 5 6 3 4...
Страница 394: ......