6. Setup and activation
29
6.5 Connect to electrical power supply
Check the power supply before connecting. Incorrect connections can cause destruction of elec-
trical equipment.
Warning!
Electrocution hazard!
Only professional electricians may connect the machine to the power supply
according to the electro-technological regulations.
For longer unattended break from work or shutdown of the machine pull mains
plug (main switch function).
Caution!
Loosely laid cables are a tripping hazard!
Lay the power cable to the machine so that it does not pose a tripping hazard.
E.g. cable bridges or connections along the ceiling can be used.
Attention!
Faulty connection values may cause material damage to machine!
Therefore, observe the machine's connection values (see Chap. 3.6 on p. 17).
The specifications on the type label must agree with the data of the electricity
grid.
Connect the electrical equipment only at a power supply witch is adequately
secured against overcurrent.
Attention!
No function of the electric brake in case of power failure!
In case of power failure, the electronic brake has no function. Here, the machine
must not be run out unattended. Do not reach into the danger zone.
Attention!
Avoid short switching cycles!
Because of the enormous thermal stress during the frequent starting and braking
the motor, the electrical box and the electronic brake can be damaged.
BSM 630
Содержание BSM 630
Страница 2: ...Status 11 2015 Eugen Riexinger GmbH Co KG...
Страница 6: ......
Страница 24: ......
Страница 34: ......
Страница 42: ......
Страница 55: ...9 Maintenance 53 9 5 1 Diversion wheels Ideally all three diversion wheels are in the same plane BSM 630...
Страница 62: ...60 9 Maintenance Date Activity Next maintenance Name BSM 630...
Страница 68: ...66 11 Annex BSM 630...
Страница 69: ...11 Annex 67 11 4 Circuit diagram BSM 630...
Страница 70: ......