STEP BY STEP command
3,15 (com)
14
/
NO
See settings for dip 1 and 2 (part. 19 fig. A)
P/P
Receiver aerial input
Output for auxiliary device power
supply
Output for Transmitter / Photocell
power supply
Indicator light output
Uscita per spia di segnalazione
allarmi
Alarm indicator light output
WARNING LAMP output
Contact for selectable functions
Encoder sensor input motor M1
Encoder sensor input motor M2
Output motor M1
Output motor M2
41
Calza
42
Cent.
35
(+)
36
37
(+)
38
39
(+)
40
29
(+)
30
31
(+)
32
33
(+)
34
26
(no)
27
(nc)
28
(c)
18
(-)
19
(+)
20
(D)
23
(-)
24
(+)
25
(D)
16
(+
open
)
17
open
(-
)
21
(+
open
)
22
open
(-
)
Function / Device
Term. n.
/
/
/
/
/
/
/
/
/
/
/
/
/
/
24dc/0,5A
24dc/
A
0,5
24dc/
A
0,2
24dc/
A
0,2
12dc/1,5A
24Vdc/1A
/4A
5-12V
5-12V
24/5A
24/5A
V/I max
Antenna connection for the OC2 module (optional)
inserted into slot det. 12, fig. A.
Use an antenna with characteristics compatible with
the receiver.
e.g. photocells, external receivers or other 24Vac
devices
Output only active during the manoeuvre and the
reclosing pause period, connect the photoelectric
cell projectors so that the minimum amount of
power is used. If the jumper (part. 9 di fig. A) is set
to ON this output will be continuously active.
Status indication:
automation CLOSED – led off
during OPENING – flashes slowly
during CLOSING – flashes quickly
STOP (block) – remains lit
during the RECLOSING PAUSE – double flashing
with pause
3 flashes indicate “obstacle detected”
4 flashes indicate “encoder not present”
5 flashes indicate “motor control failure”
6 flashes indicate “maintenance alarm”
Attiva per qualche secondo ad ogni inizio apertura.
Output active while the motor is working
With DIP 5 (part. 19 fig. A) ON, the warning-light
lights up 5 s before the motor begins to move.
Potential free contact.
See settings for dip 7 (part. 19 fig. A)
This device will be detected if it is present during
programming, otherwise it will be excluded.
This device will be detected if it is present during
programming, otherwise it will be excluded.
Motor M1 moves first in the opening direction and is
delayed during closing.
An eventual electric lock should be fitted to this gate
leaf.
M2 is the second motor to move and the first one to
close.
Notes
24V
24V FT
M1
M2
US1
ENC
1
ENC
2
12V
24V
24V
24V
GB
43
44
ELECTRIC CONNECTIONS
GB
Safety edge input
Cuts in during CLOSING
Safety edge input
Cuts in during OPENING
Photoelectric cell input
Photoelectric cell input
Input for selectable functions
Input for selectable functions
STOP button input
PEDESTRIAN command input
Command input
CLOSE
Command input
OPEN
power supply input
3,15 (com)
4
3,15 (com)
5
3,15 (com)
6
3,15 (com)
7
3,15 (com)
8
3,15 (com)
9
3,15 (com)
13
3,15 (com)
12
3,15 (com)
10
3,15 (com)
11
1
(L)
2
(N)
Function / Device
Term. n.
/
/
/
/
/
/
/
/
/
/
/
/
8K2/NC
8K2/NC
NC
NC
-
-
NC
NO
NO
NO
230/1A
V/I max
Input for closing direction enabled. Connect 8,2K safety
edges or an N.C. contact with 8,2K resistance in series (fig.
E). If unused (binding post free), set dip 1 to ON (part. 23 fig.
A).
Input for opening direction enabled. Connect 8,2K safety
edges or an N.C. contact with 8,2K resistance in series (fig.
E). If unused (binding post free), set dip 2 to ON (part. 23 fig.
A).
Travel direction inversion during closing.
If unused (binding post free), set dip 3 to ON (part. 23
fig. A).
Temporary movement block during the opening stage.
Travel direction inversion during closing.
If unused (binding post free), set dip 4 to ON (part. 23
fig. A).
See dip-switch setting 3 and 4 (part. 19 fig. A).
If unused, set dips 3 and 4 to OFF and then set dip
5 (part. 23 fig. A) to OFF.
See dip-switch setting 3 and 4 (part. 19 fig. A).
If unused, set dips 3 and 4 to OFF and then set dip
6 (part. 23 fig. A) to ON.
Blocks all functions.
If unused, set dip 7 to ON (part. 23 fig. A)
With a 2 motor installation, only M1 opens.
With a 1 motor installation it opens partially for a set
amount of time (see “programming pedestrian
opening”).
CLOSING only command, during opening it inverts
and closes.
OPENING only command, during closing it inverts
and opens.
Connect to the 230V power supply.
Notes
BSC
BSA
FT1
FT2
J1
J2
STP
PED
PC
PA
230V
8K2*
8K2*
Содержание Cardin T624
Страница 3: ...222 190 150 50 118 280 220 Fig B mm 2 ...
Страница 80: ...ZVL609 00 ...