Troubleshooting
–
What now?
Rieber GmbH & Co. KG
61
9
Troubleshooting
–
What now?
9.1
Notes on troubleshooting
WARNING
Danger of electric shock. Dangerous electrical voltage.
►
Switch off damaged electrical appliance immediately, pull connecting plug from the
mains.
►
Have all electrical repairs carried out by an authorised electrician only.
►
Any interference in the ‘plasma generator’ is forbidden, as considerable health risks
can arise.
Any repairs during warranty period may only be carried out by the Rieber service department. Please
contact the manufacturer's service department at Rieber.
Fault
Possible cause
Possible remedy
Cooking units do not
work
Connecting plug is not
plugged in
➢
Plug in the connecting plug.
#
Operating staff
Power supply disrupted
➢
Malfunction
Completely disconnect the unit
from the mains. Then switch back
on.
#
Operating staff
‘ON/OFF pushbutton
with indicator light’
does not illuminate
Device not connected
correctly
Power supply disrupted
➢
Check electrical connection.
#
Operating staff
Power supply disrupted
(Circuit breakers are located
on the left and right behind
the switch panels)
➢
Electrical hazard
Completely disconnect the unit
from the mains after a power
failure.
➢
Check status
➢
Then switch back on.
#
Qualified electrician
Smoke and odours
Temperature of cooking units
set too high
➢
Set temperature to maximum
250 °C.
#
Operating staff
High-performance grease
separator, grease drip trays,
filter mats
➢
Risk of fire
Check status
Page 49
#
Operating staff