![Rieber ACS 1600 O3 Digital Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/rieber/acs-1600-o3-digital/acs-1600-o3-digital_operating-instructions-manual_1459136030.webp)
Use
30
Rieber GmbH & Co. KG
Avoid risks from the chilling compartment (option)
Risk of slipping and falling
If the compartment is not filled with adequately pre-chilled food, condensation may form
and run out of the door. Risk of slipping and falling due to human error.
►
Only fill the compartment with adequately pre-chilled, packaged/wrapped food.
Introduce food pre-chilled to storage temperature.
►
Immediately after filling the compartment close it and do not open again until just
before serving.
►
Empty and clean the refrigerated compartment at least 1x daily. Do not use
incorrectly for continuous cooling.
Avoid general known risks due to electricity
➢
Connect the appliance to a socket with a series-connected residual current operated device (RCD)
with a tripping current of 30 mA.
A qualified electrician can technically assess the need for potential equalisation.
➢
Have the equipotential bonding carried out by a qualified electrician.
➢
Before each use, inspect the product, the connecting plug and electric cable for any visible signs
of damage.
➢
The cable must be routed so that it cannot be squeezed or overheated.
➢
The socket outlet must be easily accessible so that the unit can be disconnected from power
supply at anytime.
➢
Never direct a jet of water at electrical components such as heater, controller or ventilation grille.
Avoid risks due to electricity
→ equipotential bonding
A qualified electrician can technically assess the need for potential equalisation.
➢
Have potential equalisation carried out by a qualified electrician if necessary.
If more than one cooking unit is placed in the placement niche of the acs, these cooking units must be
connected together using their equipotential bonding (which is also located on the base of these units).
One of these cooking units is then connected to the equipotential bonding system of the acs.
If only one cooking unit is used, this must also be connected to the equipotential bonding system of the
acs.
If several acs
®
1600 O
3
appliances are placed next to each other, these should also be connected
together, to equalise any difference in voltage (static charge).