Safety instructions
14
Rieber GmbH & Co. KG
3.6.8
Safety and monitoring devices
# Sensors for condition monitoring
1
High-performance grease separator, 4 pcs.
3
Grease drip trays; 4 pcs.
7
Pressure sensor
8
Connection to equipotential bonding
When the system is started, the pressure conditions (7) are monitored within around
1 minute
. In the
event of pressure loss or a deviation of around 20% from the nominal condition, the plasma generator
is stopped. The fans are not stopped.
# More
•
The circuits are protected by 8 circuit-breakers. The respective circuit-breaker must be
switched on again.
(Circuit breakers are located on the left and right behind the switch panels)
•
Interruptions in the power supply do not cause malfunctions.
•
High-performance grease separator (1) (100% flame propagation proof) with Cyclone
®
blade
profile (separation efficiency approx. 95%).
•
The pressure sensor (7) monitors the pressure conditions in the technical compartment. In
the event of a fault the plasma generator is switched off, for example if the technical
compartment is opened.
•
In addition to protection against electric shock and in order to ensure that the frames of
electrical equipment and any external conductive components are at an equal (or practically
equal) potential, the appliance must be connected to the equipotential bonding system.
The connection of all conductive bodies (housing) of electrical equipment to an earthed
protective conductor and the main earthing bar is the basic principle for protection against
electric shock. A qualified electrician can technically assess the need for potential
equalisation. Have the equipotential bonding carried out by a qualified electrician.
See chapter ‘
Safety information with regard to use
’, page
29 et seqq.