Notes on troubleshooting
WARNING
Danger of electric shock. Dangerous electrical voltage.
►
Repairs may only be carried out by specialists
►
Any interference in the ‘plasma generator’ is forbidden.
In the event of a fault a continuous acoustic tone is emitted.
➢
Press
ON/OFF
button (1).
▌
The fan control is switched off.
➢
Press the RESET button.
▌
The continuous tone stops.
➢
Eliminate the fault or arrange for repair by a specialist.
7.2.5
Messages and measures for fault elimination
A fault is indicated in the display. If several faults are present at the same time, the fault with the
highest priority is displayed. The fault display replaces the fan operating state display. Faults (7), (8),
(9) remain illuminated until they have been eliminated and acknowledged.
Check for possible errors:
➢
Is the technical compartment closed?
➢
Are the filters in the technical compartment free from objects?
➢
Are the Eisfink active carbon filters correctly inserted?
➢
Are the high-performance grease separators, grease drip trays and filter mats
correctly mounted in the air supply area?
➢
Is the fan defective? No air flow?
Check for possible errors:
➢
Is the technical compartment closed?
➢
Is the plug of the radial fan / plasma generator inserted?
➢
Are the active carbon filters correctly positioned?