SERVICE CALL CODE TABLE
C262/C265 4-8
SM
Code Title
Conditions
Possible
Causes
SC725
Paper table motor
lock – LCOT
The paper table upper limit sensor
or lower limit sensor does not
change the status for more than 15
seconds after the paper table motor
on signal is generated.
•
Defective sensor
•
Defective motor
•
Mechanism blocked by
foreign material
ACU
SC818
Watch-dog error
While the system program is running,
other processes do not operate at all.
•
Defective ACU board
•
Software error (ACU)
SC819
Kernel panic error Processing cannot be continued by
kernel
•
Software error (ACU)
SC820
Self-Diagnostic
Error: CPU
The central processing unit returned
an error during the self-diagnostic
test.
•
ACU board defective
•
Software defective (ACU)
SC821
Self-Diagnostic
Error: ASIC
The ASIC returned an error during
the self-diagnostic test because the
ASIC and CPU timer interrupts were
compared and determined to be out
of range.
•
ACU board defective
SC822
Self-Diagnostic
Error: HDD
The hard disk drive returned an error
during the self-diagnostic test.
•
HDD defective
•
HDD connector defective
•
ACU board defective
SC823
Self-diagnostic
Error: NIC
The network interface control
returned an error during the self-
diagnostic test.
•
Defective ACU board
SC824
Self-diagnostic
Error: NVRAM
The resident non-volatile RAM
returned an error during the self-
diagnostic test.
•
NVRAM of ACU board
damaged or abnormal
•
ACU board defective
•
NVRAM socket damaged
SC826
Self-diagnostic
Error: NVRAM
The NVRAM returned an error during
the self-diagnostic test.
•
NVRAM of ACU board
defective
SC827
Self-diagnostic
Error: RAM
The resident RAM returned a verify
error during the self-diagnostic test.
•
Defective ACU board
SC828
Self-diagnostic
Error: ROM
The resident read-only memory
returned an error during the self-
diagnostic test.
•
ACU board defective
•
Firmware defective
(ACU)
SC829
Self-diagnostic
Error: DIMM-RAM
The DIMM-RAM returned an error
during the self-diagnostic test.
•
DIMM-RAM defective
•
ACU board defective
SC835
Self-Diagnostic
Error: Centro
device
Loopback test error.
•
Loopback connector not
detected
•
IEEE1284 connector
defective
•
ACU board defective
SC836
Self-diagnostic
Error: Resident
Font ROM
The resident font ROM returned an
error during the self-diagnostic test.
•
Defective ACU board
SC837
Self-diagnostic
Error: Optional
Font ROM
The optional font ROM returned an
error during the self-diagnostic test.
•
Defective ACU board
SC838
Self-diagnostic
Error: Clock
generator
The setting value of the clock
generator is wrong
•
Defective ACU board
Содержание LDD250
Страница 1: ...LDD280 C262 LDD250 C265 SERVICE MANUAL 002648MIU rev 05 31 06...
Страница 2: ......
Страница 3: ...C262 C265 SERVICE MANUAL...
Страница 4: ......
Страница 5: ...C262 C265 SERVICE MANUAL 002648MIU...
Страница 6: ......
Страница 8: ......
Страница 10: ......
Страница 12: ......
Страница 24: ......
Страница 28: ...SPECIFICATIONS...
Страница 29: ......
Страница 34: ...INSTALLATION...
Страница 35: ......
Страница 43: ...INSTALLATION PROCEDURE C262 C265 1 8 SM C262I044 WMFF C262I046 WMFF...
Страница 70: ...PREVENTIVE MAINTENANCE...
Страница 71: ......
Страница 74: ...REPLACEMENT AND ADJUSTMENT...
Страница 75: ......
Страница 84: ...SCANNER UNIT SM 3 9 C262 C265 Replacement Adjustment C Scanner drive motor x 1 x 2 1 spring C262R008 WMF C...
Страница 154: ...PAPER FEED SECTION SM 3 79 C262 C265 Replacement Adjustment E Paper feed assembly x 4 x 3 C262R087 WMF E...
Страница 233: ...TROUBLESHOOTING...
Страница 234: ......
Страница 259: ...SERVICE TABLES...
Страница 260: ......
Страница 321: ...DETAILED SECTION DESCRIPTIONS...
Страница 322: ......
Страница 394: ...DRUM C262 C265 6 72 SM 6 7 5 DRUM DRIVE MECHANISM C262D063 WMF C262D065 WMF C262D066 WMF A B C D E...