TRANSFER AND PAPER TRANSPORT UNIT
17 January, 2003
3-22
3.7.2 TRANSFER BELT CLEANING UNIT
NOTE:
After replacing the transfer belt cleaning unit, reset the maintenance
counter, SP7-804-17.
While pushing the lever, pull out the transfer belt cleaning unit [A] (
!
x 1).
NOTE:
1) The blade [B] may damage the belt if you do not keep pushing the lever.
2) When reassembling, check that the transfer unit release lever is put
back to the original position (
☛
3.5).
After replacing the transfer belt cleaning unit, perform forced line position
adjustment (SP5-993-002 or “Maintenance menu – Color registration - Auto Adjust”
in User Program mode).
G080R739.WMF
[A]
[B]