2.3. SYSTEM FEATURES
2.3.1. Power Saver Modes
- Power Saver Timer -
When the power saver timer expires, the machine automatically goes into a
Power Saver Mode. During the power saver mode, the fuisng lamp is turned
off or on according to the User Switch 05, bit 6 setting. All the LEDs on the op-
eration panel are turend off and "Saving Energy" is displayed on the LCD.
The CPU is not turned off during the power saver mode.
The machine returns to the standby mode in the following conditions:
•
When the document sensor is activated.
•
When any key on the operation panel is pressed.
•
When the handset goes off-hook.
Cross Reference
Power saver timer initial setting: System Switch 0B, bits 2 and 3
(1 minute, 3 minutes, 5 minutes, or Unlimited: Timer disabled)
The machine will not turn off the fusing lamp if one of the following conditions
exists.
•
Mechanical error(s)
•
Service call error(s)
De
ta
ile
d
Se
c
tio
n
De
s
c
rip
tio
n
s
June 10th, 1997
DETAILED SECTION DESCRIPTIONS
SYSTEM FEATURES
2-43
Содержание Aficio FX10
Страница 1: ...LFO AFICIO FX10 SERVICE MANUAL June 10th 1997 Subject to change...
Страница 243: ...PARTS CATALOG FOR Model LFO Europe France Asia 2 July 18 1997 Second Edition 1 July 10 1997 First Edition...
Страница 244: ...0RGHO 2 XURSH UDQFH VLD...
Страница 246: ...2 19 1 EXTERIOR 1...
Страница 248: ...4 28 30 29 2 EXTERIOR 2...
Страница 250: ...6 3 CASSETTE...
Страница 252: ...8 4 ADF UNIT 1...
Страница 254: ...10 5 ADF UNIT 2...
Страница 256: ...12 6 SCANNER 1...
Страница 258: ...14 7 SCANNER 2...
Страница 260: ...16 8 LASERUNIT...
Страница 262: ...18 9 PAPER FEED SECTION...
Страница 264: ...20 10 DEVELOPMENT UNIT...
Страница 266: ...22 39 40 41 11 FUSING UNIT...
Страница 268: ...24 12 PAPER EXIT SECTION 1...
Страница 270: ...26 13 FRAME AND ELECTRICAL SECTION 1...
Страница 272: ...28 26 14 FRAME AND ELECTRICAL SECTION 2...
Страница 274: ...30 15 OPTION CASSETTE...
Страница 276: ...34 PARTS INDEX...