G3 Switch 02
No
FUNCTION
COMMENTS
0
G3 protocol mode used
0: Standard and
non-standard
1: Standard only
1: Disables NSF/NSS signals (these are used in
non-standard mode communication).
1-4
Not used
Do not change the settings.
5
Use of modem rate history
when dialing using
Quick/Speed dials
0: Disabled
1: Enabled
0: Communications using Quick/Speed dials always
start with the highest modem rate.
1: The machine uses the modem rate history for
communications with the same machine when
determining the most suitable rate for the current
communication.
6
AI short protocol
(transmission and reception)
0: Disabled 1: Enabled
Refer to Appendix B in the Group 3 Facsimile Manual
for details about AI Short Protocol.
7
Short preamble
0: Disabled 1:Enabled
Refer to Appendix B in the Group 3 Facsimile Manual
for details about Short Preamble.
G3 Switch 03
No
FUNCTION
COMMENTS
0
DIS detection number
(Echo countermeasure)
0: 1
1: 2
0: The machine will hang up if it receives the same DIS
frame twice.
1: Before sending DCS, the machine will wait for the
second DIS which is caused by echo on the line.
1-2
Not used
Do not change the setting.
3
ECM frame size
0: 256 bytes
1: 64 bytes
1: The machine transmits with a frame size of 64
bytes. Set this bit to 1 when the other terminal only has
a 64 byte frame size.
4
CTC transmission conditions
0: Ricoh mode (PPR x 1)
1: ITU-T mode (PPR x 4)
When using ECM, the machine will choose a slower
modem rate after receiving PPR once (Ricoh mode) or
four times (ITU-T mode).
ITU-T: New acronym for the CCITT.
5
Modem rate used for the
next page after receiving a
negative code (RTN or PIN)
0: No change 1: Fallback
1: The machine’s tx modem rate will fall back before
sending the next page if a negative code is received.
This bit is ignored if ECM is being used.
6-7
Not used
Do not change the setting.
G3 Switch 04
FUNCTION
COMMENTS
0
to
3
Training error detection
threshold
0 - F (Hex); 0 - 15 bits
If the number of error bits in the received TCF is below
this threshold, the machine informs the sender that the
training has succeeded.
4-7
Not used
Do not change the settings.
SERVICE TABLES AND PROCEDURES
June 10th, 1997
BIT SWITCHES
4-36
Содержание Aficio FX10
Страница 1: ...LFO AFICIO FX10 SERVICE MANUAL June 10th 1997 Subject to change...
Страница 243: ...PARTS CATALOG FOR Model LFO Europe France Asia 2 July 18 1997 Second Edition 1 July 10 1997 First Edition...
Страница 244: ...0RGHO 2 XURSH UDQFH VLD...
Страница 246: ...2 19 1 EXTERIOR 1...
Страница 248: ...4 28 30 29 2 EXTERIOR 2...
Страница 250: ...6 3 CASSETTE...
Страница 252: ...8 4 ADF UNIT 1...
Страница 254: ...10 5 ADF UNIT 2...
Страница 256: ...12 6 SCANNER 1...
Страница 258: ...14 7 SCANNER 2...
Страница 260: ...16 8 LASERUNIT...
Страница 262: ...18 9 PAPER FEED SECTION...
Страница 264: ...20 10 DEVELOPMENT UNIT...
Страница 266: ...22 39 40 41 11 FUSING UNIT...
Страница 268: ...24 12 PAPER EXIT SECTION 1...
Страница 270: ...26 13 FRAME AND ELECTRICAL SECTION 1...
Страница 272: ...28 26 14 FRAME AND ELECTRICAL SECTION 2...
Страница 274: ...30 15 OPTION CASSETTE...
Страница 276: ...34 PARTS INDEX...