24
Rev 20A
All changes to these settings must be completed by a licensed electrician
J1 Terminal:
Terminal 5:
Common (Ground).
Terminal 6:
Photocell input (Normally Closed). If no photocell
is fitted use jumper between terminals 5 & 6.
Terminal 7:
Extra power input +24VDC.
J7 Terminal:
Terminal 1:
Optional External Open Push Button Switch.
(Hard Wired keypad connection between terminals 1 & 4)
Terminal 2:
Optional External Close Push Button Switch.
Terminal 3:
Optional External Stop Push Button Switch.
Terminal 4:
Common Terminal for All Optional Push Buttons.
J10 Terminal:
Factory Fitted (pre-wired)
CL:
Close Magnetic Limit Switch.
COM:
Limit Switch Common Terminal.
OP:
Open Magnetic Limit Switch.
Please note:
the CL & OP wires will need to be swapped over if the gate
direction is changed
Connecting Wires to the Terminal:
Using a screwdriver,
loosen the screw on the
side of the terminal.
Insert the wire into the
number on the terminal
that you are looking to
connect to. Refer to
Pages 18 & 19
Tighten with a
screwdriver to secure
the wire in place.