Step 9
– Testing and Adjusting the Magnetic Limit Travel Stops:
Testing the closed position
•
Ensure motor is plugged in as per step 8 and the gate is in the open position.
•
Press remote (remotes included in kit are factory paired to the motor). The gate
will begin to close.
•
The gate will stop when the magnetic limit travel stop reaches the magnetic limit
switch sensor during closing (refer to figs 19 and 20).
•
When the gate stops, measure the distance remaining between the gate and the
desired closed position.
•
You have now determined the closed position of the gate when the travel limit
stop passes the magnetic limit switch sensor.
•
Adjust the magnetic limit travel stop from the measurement you have taken to
get your desired closed position. The ideal closed final position for the gate
frame is 10-15mm from the closed gate end catch (GTR019).
Testing the open position
•
Press remote.The gate will begin to open.
•
The gate will stop when the magnetic limit travel stop reaches the magnetic limit
switch sensor during opening (refer to figs 19 and 20).
•
When the gate stops, measure the distance remaining between the gate and the
desired open position.
•
You have now determined the open position of the gate when the travel limit stop
passes the magnetic limit switch sensor.
•
Adjust the magnetic limit travel stop from the measurement you have taken to
get your desired open position. The ideal open final position for the gate frame is
10-15mm from the gate stopper (GTR017).
To Reset:
When setting new limit stop positions please ensure that you turn the power off for at least 15
seconds and then on again. Turning the power off will reset the limit stop memory, allowing for
new limit travel stop positions to be recognised by the motor.