![RHINO RMCS -2303 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/rhino/rmcs-2303/rmcs-2303_operating-manual_1452492007.webp)
Page | 7
How to use the drive:
The drive needs to be configured to run in any one of the three modes described in the above section to make a
closed loop control system. The drive can be configured using a PC with Modbus Poll software / Modbus controller /
Arduino Board. We shall be discussing the configuration through Modbus Poll software in this document.
To describe the configuration of the drive for a closed loop system we shall be using the following:
1. PC with Modbus Poll software. ( The modbus poll software can be downloaded from the link -
https://www.modbustools.com/download.html
2. RMCS-2303 UART ASCII Encoder DC Motor Driver
3. Encoder DC Servo Motor ( any of the below motors would work with the drive)
https://robokits.co.in/rhino-planetary-encoder-dc-servo
https://robokits.co.in/rhino-ig32-precision-dc-servo
https://robokits.co.in/motors/encoder-dc-servo/high-torque-dc-encoder-motor
https://robokits.co.in/motors/encoder-dc-servo/high-torque-high-precision-motor
4. Industrial Power Supply (below is a recommended supply. It can vary as per your requirements)
https://robokits.co.in/power-supply/industrial-power-supply/24v-10a-industrial-power-supply
5. RKI-1154 CP2102 USB UART Module
https://robokits.co.in/control-boards/interface-boards/cp2102-usb-uart-module
6. External 10K Potentiometer (for analog Speed Control mode only).
7. Voltage divider from 5V to 3.3V or Voltage converter from 5V to 3.3V (for analog speed control mode only).
Steps to configure the Drive using Modbus Poll Software :
1. Hardware Connection
2. Connect Modbus UART ASCII drive with Modbus Poll Software
3. Set Slave ID in Read/Write Function according to the physical jumper or software settings
4. Go to Function-Write Single register
5. Set the Lines per rotation as per the encoder and motor specifications
6. Set one of the three user Mode as per requirement
7. Save and Reset the settings in drive