STEP 7: Save and Reset settings in Drive
a) To save settings in drive send Hex value 07FF to address 0. If user saves setting in drive then user just
need to power up drive then motor will run according to saved setting. Users
don’t need to connect the drive
through software again to run the motor. In hex value 07FF 07 is slave ID and FF value is ignored.
b) To Reset setting in drive send Hex value 0 to address 4 as per below image then save to eeprom by
sending Hex value 07FF to address 0. Then on power reset the drive will have original parameters.
c) This concludes
STEP 7
of the configuration procedure.