![RHINO RMCS -2303 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/rhino/rmcs-2303/rmcs-2303_operating-manual_1452492022.webp)
Page | 22
d) Now we need to set speed in digital speed control mode. The Speed is as per rpm of base motor. Eg. For a
base motor with 18,000 rpm and the gear ratio of 180, the motor at maximum rpm would be 100 rpm at
output shaft. So to set maximum RPM for the motor we would have to program 4650 (HEX value of 18000)
in the value and send. To set 50 RPM output for the motor, we would have to set 50% rpm for the base
motor. So we would set 2328 (HEX value of 18000) in the register 14. In the below image we have set the
HEX value of 1000 which gives 4096 rpm to base motor.
e) After speed setting user needs to enable motor by sending Hex value 0101 to address 2 as per below
image.