The bracket furthest from the burner must
be installed with the flange and reflector
fixing tabs facing away from the burner end
of the heater. All other brackets must have
the flanges facing towards the burner end.
Slide the bracket assemblies along the tubes
to the correct position and in the correct
order (15-25kW models have a different
first U-Bolt). Tighten all U-Bolt nuts. Refer
to detailed assembly drawing (Figure 41 to
Figure 50) for more details.
2.2.5 Connecting the U-Bend.
Locate and position tube couplers at the
end of the tubes so that the socket heads
are facing upwards towards the welded
seam. Make sure the pre-fitted bolts in the
couplers engage with the 13mm locating
holes in the tubes.
Slide U-Bend into open end of the couplers
and ensure the 13mm locating holes in the
U-Bend engage with the pre-fitted bolts in
the couplers.
Tighten socket head clamping bolts on both
couplers, alternating between bolts until
fully secure. Re-check bracket positions
and tighten all U-Bolt nuts.
CAUTION
To avoid damage to the heater whilst
completing installation we recommend
the heater chassis be suspended prior
to fitting reflectors.
Looking from above
the heater
Burner End
Bracket furthest from burner has flange facing
away from burner end.
Burner end bracket and all intermediate brackets have
flange facing towards burner end.
Coupler pins to engage
with holes in tubes
Socket heads
facing upwards
Figure 26.6
U-Bolt to U-Tube heater suspension brackets
Figure 27.
U-Bolt to U-Tube heater suspension brackets
Looking from above the heater
28
Содержание VS15LHE8
Страница 34: ...A Figure 41 Vision Heater Assembly Models VSUTE VSUHE 15kW 76mm 3ins Nom Dia 34...
Страница 35: ...A A Figure 42 Vision Heater Assembly Models VSUTE VSUHE 20 25kW 76mm 3ins Nom Dia 35...
Страница 36: ...Figure 43 Vision Heater Assembly Models VSUTE VSUHE 30 35kW 100mm 4ins Nom Dia 36...
Страница 37: ...Figure 44 Vision Heater Assembly Models VSUTE VSUHE 40kW 100mm 4ins Nom Dia 37...
Страница 38: ...Figure 45 Vision Heater Assembly Models VSUTE VSUHE 45 50kW 100mm 4ins Nom Dia 38...
Страница 39: ...A Figure 46 Vision Heater Assembly Models VSLIE VSLHE VSDLE 15 25kW 8m 76mm 3ins Nom Dia 39...
Страница 40: ...A Figure 47 Vision Heater Assembly Models VSLIE VSLHE VSDLE 20 25kW 10 5m 76mm 3ins Nom Dia 40...
Страница 41: ...Figure 48 Vision Heater Assembly Models VSLIE VSLHE VSDLE 30 35kW 10 5m 100mm 4ins Nom Dia 41...
Страница 42: ...Figure 49 Vision Heater Assembly Models VSLIE VSLHE VSDLE 30 35 40 45 50kW 13 5m 100mm 4in Nom Dia 42...
Страница 43: ...Figure 50 Vision Heater Assy Models VSLIE VSLHE VSDLE 35 40 45 50 kW 16m 100mm 4ins Nom Dia 43...