IMPORTANT NOTICE TO INSTALLERS
Installers should satisfy themselves that
the fuel pipework installation is carried out
in accordance with all current legislation,
Codes of Practice and recommendations.
Additionally it may be necessary to protect
the fuel valves which form part of the
heater or burner assembly from potential
pipe contamination particularly, but not
exclusively, where copper gas pipework is
used. In instances where copper pipework
is to be used for all or part of a gas pipework
installation, including short length final
connections then we advise that installers
consult with gas supplier or provider and
satisfy themselves what additional precau-
tions may be necessary.
Improper installation, adjustment, alter-
ation, service, or maintenance can cause
property damage, injury, or death. Read the
installation, operation, and maintenance
instructions thoroughly before installing
or servicing this equipment.
Do not use this appliance if any part has
been immersed in water. Immediately call
a qualified service technician to inspect the
appliance and replace any gas control that
has been immersed in water.
These appliances are not designed for use
in hazardous atmospheres containing
flammable vapours or combustible dust,
in atmospheres containing chlorinated or
halogenated hydrocarbons or in applica-
tions with airborne silicone substances.
Should overheating occur, or the fuel supply
fail to shut off, close the manual fuel valve
to the appliance before shutting off the elec-
trical supply.
This appliance is not intended for use by
persons (including children) with reduced
sensory or mental capabilities or lack of
experience and knowledge, unless they
have been given supervision or instruction
concerning use of the appliance by a person
responsible for their safety. Children should
be supervised to ensure that they do not
play with the appliance.
Any reference made to laws, standards,
directives, codes of practice or other recom-
mendations governing the application
and installation of heating appliances and
which may be referred to in brochures,
specifications, quotations, and installa-
tion, operation and maintenance manuals
is done so for information and guidance
purposes only and should only be consid-
ered valid at the time of the publication.
The manufacturer cannot be held respon-
sible from any matters arising from the
revision to or introduction of new Laws,
Standards, Directives, Codes of Practice
or other recommendations.
Failure to comply with the information given with these symbols will result in severe personal injury or death and/or property damage.
WARNING
CAUTION
WARNINGS:
For your safety, if you smell gas:
• Do not try to light any appliance
• Do not touch any electrical switch, do not
use any phone in your building
• Evacuate all personnel & contact your gas
supplier immediately
• Do not store or use petrol or other
flammable vapours and liquids in the
vicinity of the appliance.
• Improper installation, adjustment,
alteration, service or maintenance can
cause property damage, injury or death.
• Read the installation, operation and
maintenance instructions thoroughly
before installing or servicing this
equipment.
• In case of persisting problems, contact
your distributor
2
Содержание VS15LHE8
Страница 34: ...A Figure 41 Vision Heater Assembly Models VSUTE VSUHE 15kW 76mm 3ins Nom Dia 34...
Страница 35: ...A A Figure 42 Vision Heater Assembly Models VSUTE VSUHE 20 25kW 76mm 3ins Nom Dia 35...
Страница 36: ...Figure 43 Vision Heater Assembly Models VSUTE VSUHE 30 35kW 100mm 4ins Nom Dia 36...
Страница 37: ...Figure 44 Vision Heater Assembly Models VSUTE VSUHE 40kW 100mm 4ins Nom Dia 37...
Страница 38: ...Figure 45 Vision Heater Assembly Models VSUTE VSUHE 45 50kW 100mm 4ins Nom Dia 38...
Страница 39: ...A Figure 46 Vision Heater Assembly Models VSLIE VSLHE VSDLE 15 25kW 8m 76mm 3ins Nom Dia 39...
Страница 40: ...A Figure 47 Vision Heater Assembly Models VSLIE VSLHE VSDLE 20 25kW 10 5m 76mm 3ins Nom Dia 40...
Страница 41: ...Figure 48 Vision Heater Assembly Models VSLIE VSLHE VSDLE 30 35kW 10 5m 100mm 4ins Nom Dia 41...
Страница 42: ...Figure 49 Vision Heater Assembly Models VSLIE VSLHE VSDLE 30 35 40 45 50kW 13 5m 100mm 4in Nom Dia 42...
Страница 43: ...Figure 50 Vision Heater Assy Models VSLIE VSLHE VSDLE 35 40 45 50 kW 16m 100mm 4ins Nom Dia 43...
Страница 59: ...Notes 59...