44
ENGLISH
GB
Fuse replacement and thermal relay rearm
The fuses (
E
) and the thermal relay (
F
) are
in the lower part of the blast chiller. To access this
remove the lower control panel using the same
method listed for the access and cleaning of the
condenser.
U.V. Lamp Replacement
To access the evaporator proceed as follows:
1.
Open the door (
A
) of the appliance.
2.
Remove the runners (
B
):
3.
Loosen the two screws (
C
) on the front of the
deflector.
4.
Turn the deflector (
D
) to the right.
Once the deflector is turned, it is possible to
switch the UV lamp on. This lamp can be
removed by sliding it upwards (
E
). Carry out all
the operations in reverse order after having
removed the U lamp.
6.6.
Extraordinary Maintenance 10T
2/1
Have the following operations carried out
periodically
by specialised staff:
Check the perfect sealing of the door
gaskets and replace them if necessary.
Check that the electric connections have
not loosened.
Check the efficiency of the heating
element resistance
Check functioning of the board and
probes.
Check the efficiency of the electrical
system.
Clean the evaporator.
Clean the condenser.
D
C
B
A
E
E F
Rearm the thermal relay
using the grey button