13
ENGLISH
GB
Temperature Frosting Cycle
This cycle lowers the temperature at the
core of the product from
+ 90 ° C
to
- 18 ° C
in the
shortest time possible and within a maximum time
of
270 minutes
. The end of the cycle is
determined by the achievement of the value
- 18 °
C
read by the core probe.
Selecting the freezing cycle, the system displays
following screenshot :
By default the system suggests the temperature
cycle.
By pressing the area
it is
possible to change the operating cell temperature.
By pressing the area
it is
possible to change the product temperature at the
end of the cycle.
By pressing the area
it is
possible to change the fan speed during frosting.
Pressing the area
it is possible to change
the cell temperature
and the speed of the
fans
during the conservation phase.
Press the area
to enable the SOFT phase:
the relative area will be enlightened
.
In this case the frosting cycle will be divided into
three stages :
SOFT frosting
standard
frosting
conservation
Pressing the
area, the controller displays
the “advanced setting” screen :
Within this mode, following values can be
changed :
cell temperature
during the SOFT phase ;
product
temperature at the end of the SOFT cycle;
cell temperature
during the conservation phase ;
fan speed during the SOFT
phase ;
fan speed during the
conservation.
To exit the “advanced settings” screen press
on the upper left display area.
To confirm the frosting cycle settings press the
right lower area
.