
111
en
Healthbox
®
II (Compact) & Healthbox
®
Smartzone
Empty House Mode
System without demand control at lower system pressure.
All valves at minimal rate.
Lowest ventilation rate, e.g. when no one is at the house.
Cooking Mode
Nearly the full system’s capacity is directed towards extraction of
contaminated air in the kitchen.
Can be used to control a cooker hood without motor.
02:35
1
Light Breeze Mode
System with partial demand-driven control at lower system pressure.
• VOC and humidity-controlled valves: in nominal position
• CO
2
-controlled valves: Ventilator air flow control according to sensors
in the valves
Full Breeze Mode
System without demand-driven control at nominal system pressure. All
valves in nominal position (= C-mode).
E.g. When there is a need for cooling in the apartment and the outdoor
climate allows, the fresher outdoor air is delivered with a higher air flow.
Breeze Mode
The intensity of the activated Breeze mode depends on the setting of dip
switch DIP 3 (see section 8.6 “Setting dip switches”)
Содержание Healthbox II
Страница 1: ...Handbuch Manual Software version 0 6 40 Healthbox II Compact Healthbox Smartzone HEALTHBOX Breeze...
Страница 61: ...de Healthbox II Compact Healthbox Smartzone 61...
Страница 121: ...121 en Healthbox II Compact Healthbox Smartzone 121...
Страница 122: ...122 Healthbox II Compact Healthbox Smartzone...
Страница 123: ...123 Healthbox II Compact Healthbox Smartzone...