Action:
Press longer (> 5 sec.)
Display: LED blinks SLOWLY
for 10 hours
after 10 hours, ECO-LED
will be on permanently
eco
eco
eco
8.2.5 • Breeze Mode
8.2.5.1 • Light Breeze Mode
System with partial demand control at lower system pressure.
• VOC and humidity-controlled valves: in nominal position
• CO
2
-controlled valves: control of ventilator air flow according to sensors in the valves
Note:
– On the Healthbox [printed circuit board type V6] this ventilation mode can only be used
if dip switch 1 on the printed circuit board is set to ON (see section 8.ó “Setting dip
switches”).
Action:
Press briefly
Display: LED 7 hours
continuously on
after 7 hours, ECO-LED
will be on permanently
Fan unit will fan for
7 hours
in Light Breeze Mode;
afterwards, EcoMode is
automatically switched on
eco
eco
eco
8.2.5.2 • Full Breeze Mode
System without demand-driven control at nominal system pressure. All valves in nominal position
(= C-mode). E.g. When there is a need for cooling in the apartment and the outdoor climate
allows, the fresher outdoor air is delivered with a higher air flow.
Note:
– On the Healthbox [printed circuit board type V6] this ventilation mode can only be used
of dip switch 3 on the printed circuit board is set to ON (see section 8.ó “Setting of dip
switches”).
Fan unit will fan for
10 hours
in Boost Mode;
afterwards, EcoMode is
automatically switched on
Содержание Healthbox II
Страница 1: ...Handbuch Manual Software version 0 6 40 Healthbox II Compact Healthbox Smartzone HEALTHBOX Breeze...
Страница 61: ...de Healthbox II Compact Healthbox Smartzone 61...
Страница 121: ...121 en Healthbox II Compact Healthbox Smartzone 121...
Страница 122: ...122 Healthbox II Compact Healthbox Smartzone...
Страница 123: ...123 Healthbox II Compact Healthbox Smartzone...