![Renson Endura Delta 330 Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/renson/endura-delta-330/endura-delta-330_installer-and-user-manual_1443062047.webp)
47
Endura
®
Delta
en
Installer
e) Setting input and output
You can determine the functions for the set input and output contacts using this menu. These
functions are listed below.
Select the desired
contact that you
would like to
configure.
Change the function
according to the table
below and then tap
“Save”. The function
is active if the input/
output contact is
externally controlled.
Attention!
Deviation from the normal operation of the unit by using the input/output contacts to then
control the fans based on your own logic is entirely at your own risk and responsibility.
The ventilation unit must continuously operate, i.e. the Endura Delta may never be turned off
(legal requirement according to NBN D50-001).
Input 1 digital open contact
Position 0 Turn off supply and discharge (fire safety)
Position 1 Turn off discharge
Position 2 Turn off supply (unit works as a C system)
Position 3 Start Fireplace function
Position 4 Reset filter
Input 2 digital open contact
Position 0 Turn off supply and discharge (fire safety)
Position 1 Turn off discharge
Position 2 Turn off supply (unit works as a C system)
Position 3 Start Fireplace function
Position 4 Reset filter
Input 3 analogue 0-10 V
contact
Position 0 Not active. The ventilation system ignores the
analogue input.
Output 1 digital open contact
Position 0 General error message
Position 1 Filter message
Output 2 digital open contact
Position 0 General error message
Position 1 Filter message
Output 3 analogue 0-10 V
contact
Position 0 Not active. The ventilation system ignores the
analogue output.