770
25.3.5
Multifunction Timer Pulse Unit Timing
Table 25.9
Multifunction Timer Pulse Unit Timing (Conditions: V
CC
= 5.0 V ± 10%, AV
CC
= 5.0 V ± 10%, AV
CC
= V
CC
± 10%, AV
ref
= 4.5 V to AV
CC
, V
SS
= AV
SS
= 0 V, Ta
= – 20 to +75
°
C)
Item
Symbol
Min
Max
Unit
Figure
Output compare output delay time t
TOCD
—
100
ns
25.23
Input capture input setup time
t
TICS
30
—
ns
Timer input setup time
t
TCKS
35
—
ns
Timer clock pulse width (single
edge specification)
t
TCKWH/L
1.5
—
t
cyc
25.24
Timer clock pulse width (both
edges specified)
t
TCKWH/L
2.5
—
t
cyc
Timer clock pulse width (phase
measurement mode)
t
TCKWH/L
2.5
—
t
cyc
CK
t
TOCD
t
TICS
Input
capture input
Output
compare output
Figure 25.23 MTU I/O Timing
CK
TCLKA
to TCLKD
t
TCKS
t
TCKS
t
TCKWH
t
TCKWL
Figure 25.24 MTU Clock Input Timing
Содержание SH7041 Series
Страница 2: ......
Страница 6: ......
Страница 38: ...xvi ...
Страница 44: ...6 ...
Страница 46: ...8 ...
Страница 48: ...10 ...
Страница 82: ...44 ...
Страница 114: ...76 ...
Страница 118: ...80 ...
Страница 124: ...86 ...
Страница 170: ...132 ...
Страница 250: ...212 ...
Страница 492: ...454 ...
Страница 506: ...468 ...
Страница 604: ...566 ...
Страница 684: ...646 ...
Страница 706: ...668 ...
Страница 778: ...740 ...
Страница 780: ...742 ...
Страница 818: ...780 ...
Страница 850: ...812 ...
Страница 923: ...SH7040 SH7041 SH7042 SH7043 SH7044 SH7045 Group Hardware Manual REJ09B0044 0600O ...