364
•
Initial output in complementary PWM mode
In complementary PWM mode, the initial output is determined by the setting of bits OLSN and
OLSP in the timer output control register (TOCR).
This initial output is the PWM pulse non-active level, and is output from when complementary
PWM mode is set with the timer mode register (TMDR) until TCNT4 exceeds the value set in
the dead time register (TDDR). Figure 12.43 shows an example of the initial output in
complementary PWM mode.
An example of the waveform when the initial PWM duty value is smaller than the TDDR
value is shown in figure 12.44.
Timer output control register settings
OLSN bit: 0 (initial output: high; active level: low)
OLSP bit: 0 (initial output: high; active level: low)
TCNT3, 4 value
TGR4A
TDDR
TCNT3
TCNT4
Initial output
Dead time
Time
Active level
Active level
TCNT3, 4 count start
(TSTR setting)
Complementary
PWM mode
(TMDR setting)
Positive phase
output
Negative phase
output
Figure 12.43 Example of Initial Output in Complementary PWM Mode (1)
Содержание SH7041 Series
Страница 2: ......
Страница 6: ......
Страница 38: ...xvi ...
Страница 44: ...6 ...
Страница 46: ...8 ...
Страница 48: ...10 ...
Страница 82: ...44 ...
Страница 114: ...76 ...
Страница 118: ...80 ...
Страница 124: ...86 ...
Страница 170: ...132 ...
Страница 250: ...212 ...
Страница 492: ...454 ...
Страница 506: ...468 ...
Страница 604: ...566 ...
Страница 684: ...646 ...
Страница 706: ...668 ...
Страница 778: ...740 ...
Страница 780: ...742 ...
Страница 818: ...780 ...
Страница 850: ...812 ...
Страница 923: ...SH7040 SH7041 SH7042 SH7043 SH7044 SH7045 Group Hardware Manual REJ09B0044 0600O ...