548
15.4
Operation
•
The high speed A/D converter has 10-bit resolution.
•
In addition to the four operating modes of select or group, and single or scan can be set in
combination with buffer operation and simultaneous sampling operation.
•
Select mode uses one channel and group mode selects multiple channels.
•
One start in the single mode performs conversions on all selected channels, and one start in the
scan mode performs repeated conversions until stopped by software.
•
In buffer operation, the previous conversion result is saved in a buffer register at the end of a
conversion for the relevant channel.
•
In simultaneous sampling operation, the analog input voltages of two channels are sampled
simultaneously then converted in order.
•
Software, a timer conversion start trigger (MTU), or an ADTRG input can be selected as the
conversion start condition.
•
High speed start mode or low power conversion mode can be selected for A/D conversion
using the PWR bit setting.
•
When changing the operation mode or input channel, rewrite the ADCSR, ADCR while the
ADST bit is cleared to 0. After rewriting the ADCSR, ADCR, A/D conversion will be restarted
when the ADST bit is set to 1. Operation mode or input channel changes can be made
simultaneously with ADST bit setting. When stopping an A/D conversion before completion, 0
clear the ADST bit.
15.4.1
Select-Single Mode
Choose select-single mode when doing A/D conversions for one channel only.
When the ADST bit is set to 1, A/D conversion is started according to the designated conversion
start conditions. The ADST bit is held to 1 during the A/D conversion and is automatically cleared
to 0 upon completion.
The ADF flag is also set to 1 at the end of conversion. If the ADIE bit is set to 1 at this time, an
ADI interrupt request is generated. The ADF flag is cleared by reading the ADCSR, then writing a
0.
Figure 15.4 shows an example of operation in the select-single mode when AN1 is selected.
Содержание SH7041 Series
Страница 2: ......
Страница 6: ......
Страница 38: ...xvi ...
Страница 44: ...6 ...
Страница 46: ...8 ...
Страница 48: ...10 ...
Страница 82: ...44 ...
Страница 114: ...76 ...
Страница 118: ...80 ...
Страница 124: ...86 ...
Страница 170: ...132 ...
Страница 250: ...212 ...
Страница 492: ...454 ...
Страница 506: ...468 ...
Страница 604: ...566 ...
Страница 684: ...646 ...
Страница 706: ...668 ...
Страница 778: ...740 ...
Страница 780: ...742 ...
Страница 818: ...780 ...
Страница 850: ...812 ...
Страница 923: ...SH7040 SH7041 SH7042 SH7043 SH7044 SH7045 Group Hardware Manual REJ09B0044 0600O ...