RX23W Group
23. Multi-Function Timer Pulse Unit 2 (MTU2a)
(21) Operation When Error Occurs in Complementary PWM Mode and Operation is Restarted in
Normal Mode
shows a case in which an error occurs in complementary PWM mode and operation is restarted in normal
mode after re-setting.
Figure 23.136
Error Occurrence in Complementary PWM Mode, Recovery in Normal Mode
(1) After a reset, the MTU output goes low and the ports enter high-impedance state.
(2) Select the complementary PWM mode output level and enable or disable cyclic output with the TOCR register.
(3) Set complementary PWM mode.
(4) Enable output in MTU3 and MTU4 with the TOER register.
(5) Use the MPC and the port mode register (PMR) for the I/O port to set up MTU output.
(6) Start count operation by setting the TSTR register.
(7) The complementary PWM waveform is output on compare match occurrence.
(8) An error occurs.
(9) Use the port direction register (PDR) and port mode register (PMR) for the input port pin to switch it to operate as a
(10) Stop count operation by setting the TSTR register. (MTU output becomes the initial complementary PWM output
value).
(11) Set normal mode (MTU output goes low).
(12) Initialize the pins with the TIOR register.
(13) Use the MPC and the port mode register (PMR) for the I/O port to set up MTU output.
(14) Restart operation by setting the TSTR register.
(1)
Reset
MTU module output
(2)
TOCR
(3)
TMDR
(CPWM)
(4)
TOER
(1)
(6)
TSTR
(1)
(7)
Match
(8)
Error
occurs
(9)
Port
output
(10)
TSTR
(0)
(11)
TMDR
(normal)
(12)
TIOR
(1 init
0 out)
(14)
TSTR
(1)
MTIOC3A
MTIOC3B
MTIOC3D
PORT output
Pxx
Pxx
Pxx
(5)
MPC
(MTU)
(13)
MPC
(MTU)
Hi-Z
Hi-Z
Hi-Z