RX23W Group
36. CAN Module (RSCAN)
36.2.37
Receive FIFO Access Register mAL (RFIDLm) (m = 0, 1)
This register can be read when the GRWCR.RPAGE bit is 1.
RFID[15:0] Bits (Receive FIFO Buffer ID Data L)
These bits indicate the ID of the message stored in the receive FIFO buffer.
36.2.38
Receive FIFO Access Register mAH (RFIDHm) (m = 0, 1)
This register can be read when the GRWCR.RPAGE bit is 1.
RFID[28:16] Bits (Receive FIFO Buffer ID Data H)
These bits indicate the ID of the message stored in the receive FIFO buffer.
RFRTR Bit (Receive FIFO Buffer RTR)
This bit indicates the frame format (data frame or remote frame) of the message stored in the receive FIFO buffer.
RFIDE Bit (Receive FIFO Buffer IDE)
This bit indicates the ID format (standard ID or extended ID) of the message stored in the receive FIFO buffer.
Address(es): RSCAN.RFIDL0 000A 85A0h, RSCAN.RFIDL1 000A 85B0h
b15
b14
b13
b12
b11
b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
RFID[15:0]
Value after reset:
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
Symbol
Bit Name
Description
R/W
b15 to b0
Receive FIFO Buffer ID Data L
The standard ID or extended ID of received message can be
read.
Read bits 10 to 0 for standard ID. Bits 15 to 11 are read as 0.
R
Address(es): RSCAN.RFIDH0 000A 85A2h, RSCAN.RFIDH1 000A 85B2h
b15
b14
b13
b12
b11
b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
RFIDE RFRTR
—
RFID[28:16]
Value after reset:
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
Symbol
Bit Name
Description
R/W
b12 to b0
Receive FIFO Buffer ID Data H
The standard ID or extended ID of received message can be
read.
For standard ID, these bits are read as 0.
R
b13
—
Reserved
This bit is read as 0.
R
b14
Receive FIFO Buffer RTR
0: Data frame
1: Remote frame
R
b15
Receive FIFO Buffer IDE
0: Standard ID
1: Extended ID
R