23. Multi-Function Timer Pulse Unit 2 (MTU2a)
(11) Operation When Error Occurs in PWM Mode 1 and Operation is Restarted in Complementary
PWM Mode
shows a case in which an error occurs in PWM mode 1 and operation is restarted in complementary
PWM mode after re-setting.
Figure 23.126
Error Occurrence in PWM Mode 1, Recovery in Complementary PWM Mode
(1) to (10) are the same as in
(11) Set normal mode to initialize the normal mode waveform generation block.
(12) Initialize the PWM mode 1 waveform generation block with the TIOR register.
(13) Disable operation of the PWM mode 1 waveform generation block with the TIOR register.
(14) Disable output in MTU3 and MTU4 with the TOER register.
(15) Select the complementary PWM mode output level and enable or disable cyclic output with the TOCR register.
(16) Set complementary PWM mode.
(17) Enable output in MTU3 and MTU4 with the TOER register.
(18) Use the MPC and the port mode register (PMR) for the I/O port to set up MTU output.
(19) Restart operation by setting the TSTR register.
(1)
Reset
MTU module output
(2)
TMDR
(PWM1)
(3)
TOER
(1)
(4)
TIOR
(1 init
0 out)
(6)
TSTR
(1)
(7)
Match
(8)
Error
occurs
(9)
Port
output
(10)
TSTR
(0)
(11)
TMDR
(normal)
(12)
TIOR
(0 init
0 out)
(13)
TIOR
(disabled)
(14)
TOER
(0)
(15)
TOCR
(16)
TMDR
(CPWM)
(17)
TOER
(1)
(19)
TSTR
(1)
MTIOC3A
MTIOC3B
MTIOC3D
PORT output
Pxx
Pxx
Pxx
(5)
MPC
(MTU)
(18)
MPC
(MTU)
Hi-Z
Hi-Z
Hi-Z
Not initialized (MTIOCnB)
Not initialized (MTIOCnD)