R01UH0823EJ0100 Rev.1.00
Page 615 of 1823
Jul 31, 2019
RX23W Group
23. Multi-Function Timer Pulse Unit 2 (MTU2a)
(4) Operation When Error Occurs in Normal Mode and Operation is Restarted in Phase Counting
Mode
shows a case in which an error occurs in normal mode and operation is restarted in phase counting mode
after re-setting.
Figure 23.119
Error Occurrence in Normal Mode, Recovery in Phase Counting Mode
(1) to (10) are the same as in
(11) Set the phase counting mode.
(12) Initialize the pins with the TIOR register.
(13) Use the MPC and the port mode register (PMR) for the I/O port to set up MTU output.
(14) Restart operation by setting the TSTR register.
Note:
The phase counting mode can only be selected for MTU1 and MTU2, and therefore the TOER register setting is
not necessary.
(1)
Reset
(2)
TMDR
(normal)
(3)
TOER
(1)
(4)
TIOR
(1 init
0 out)
(6)
TSTR
(1)
(7)
Match
(8)
Error
occurs
(9)
Port
output
(10)
TSTR
(0)
(11)
TMDR
(PCM)
(12)
TIOR
(1 init
0 out)
(14)
TSTR
(1)
(5)
MPC
(MTU)
(13)
MPC
(MTU)
MTU module output
MTIOCnA
MTIOCnB
PORT output
Pxx
Pxx
Hi-Z
Hi-Z