M30870T2-CPE User’s Manual
2. Setup
REJ10J0766-0400 Rev.4.00 February 16, 2006
2.8.3 Connecting to a 100-pin 0.65-mm-pitch Foot Pattern (Part 2)
Figure 2.14 shows how to connect the compact emulator to a 100-pin 0.65-mm-pitch foot pattern on the user system with the
M3T-DIRECT100S (not included), and here following is its procedure. For details on the M3T-100LCC-DMS and M3T-
DIRECT100S, refer to each user's manual.
(1) Attach the M3T-DIRECT100S to the user system.
(2) Attach the M3T-100LCC-DMS to the M3T-DIRECT100S.
(3) Attach the M30800T-PTC to the M30870T2-CPE.
(4) Attach the M30800T-PTC to the M3T-100LCC-DMS.
Figure 2.14 Connecting to a 100-pin 0.5-mm-pitch foot pattern (part 2)
CAUTION
Notes on Connecting the User System:
Take care not to attach a converter board in a wrong direction. It may cause a fatal damage to the emulator and
user system.
The small connectors of the M3T-100LCC-DMS and M3T-DIRECT100S are guaranteed for only 20
insertion/removal iterations.
The small connectors of the M30870T2-CPE and M30800T-PTC are guaranteed for only 50 insertion/removal
iterations.
M3T-100LCC-DMS
(not included)
M30870T2-CPE
CN2 side
(3)
(4)
M30800T-PTC
(2)
(1)
100-pin 0.65-mm-pitch
(100P6S) foot pattern
No. 1 pin
User system
M3T-DIRECT100S
(not included)
Page 33 of 102