M30870T2-CPE User’s Manual
2. Setup
REJ10J0766-0400 Rev.4.00 February 16, 2006
2.8.4 Connecting to a 100-pin 0.65-mm-pitch Foot Pattern (Part 3)
Figure 2.15 shows how to connect the compact emulator to a 100-pin 0.65-mm-pitch foot pattern on the user system with the
M3T-FLX-100NRB (not included), and here following is its procedure. For details on the M3T-100LCC-DMS and M3T-FLX-
100NRB, refer to each user's manual.
(1) Attach the M3T-FLX-100NRB to the user system.
(2) Attach the M3T-100LCC-DMS to the M3T-FLX-100NRB.
(3) Attach the M30800T-PTC to the M30870T2-CPE.
(4) Attach the M30800T-PTC to the M3T-100LCC-DMS.
Figure 2.15 Connecting to an 100-pin 0.65-mm-pitch foot pattern (part 3)
CAUTION
Notes on Connecting the User System:
Take care not to attach a converter board in a wrong direction. It may cause a fatal damage to the emulator and
user system.
The small connectors of the M3T-100LCC-DMS and M3T-FLX-100NRB are guaranteed for only 20
insertion/removal iterations.
The small connectors of the M30870T2-CPE and M30800T-PTC are guaranteed for only 50 insertion/removal
iterations.
*NQPACK, YQPACK, YQSOCKET, YQ-GUIDE, HQPACK, TQPACK and TQSOCKET are trademarks of Tokyo Eletech
Corporation.
M3T-100LCC-DMS
(not included)
M30870T2-CPE
CN2 side
(3)
(4)
M30800T-PTC
*
(2)
(1)
100-pin 0.65-mm-pitch
(100P6S) foot pattern
No. 1 pin
User system
M3T-FLX-100NRB
(not included)
FLASH MCU etc.
On-board evaluation
*
: These four items are available in one package
YQPACK100RB
NQPACK100RB
HQPACK100RB
(not included)
These corners are not round.
YQ-GUIDE(x4)
Page 34 of 102
The HQPACK100RB cannot be used.
Please use the HQPACK100RB168.