M30870T2-CPE User’s Manual
5. Troubleshooting
REJ10J0766-0400 Rev.4.00 February 16, 2006
5. Troubleshooting
This chapter describes how to troubleshoot when this product does not work properly.
5.1 Flowchart to Remedy the Troubles
Figure 5.1 shows the flowchart to remedy the troubles from when power to the emulator is activated until the emulator
debugger starts up. Check this while the user system is disconnected. For the latest FAQs visit the Renesas Tools Homepage.
http://www.renesas.com/en/tools
Figure 5.1 Flowchart to remedy the troubles
Turning on emulator
Front panel LED
of emulator
1 .
Check connection of the power supply cable.
See "2.4 Connecting the Power Supply for Emulator" (page 22)
2 . Check that the power is properly supplied to the user system.
See "2.6 Turning ON the Power Supply" (page 24)
Init dialog box of
emulator debugger displayed
1 . Check the operating environment etc., of the emulator debugger.
See the user's manual of the emulator debugger.
2 . Reinstall the emulator debugger.
MCU Setting dialog box
of emulator debugger displayed
See "5. 2 (2 ) MCU Setting Dialog Box Does Not Appear at
Debugger Startup" (page 96).
Program window of
emulator debugger displayed
See "5. 2 (3 ) Errors Occur at Debugger Startup" (page 97).
Emulator debugger startup completed
Normal
Normal
Normal
Normal
Not normal
Not normal/ Error displayed
Not normal/ Error displayed
Error displayed
Page 94 of 102