( 44 / 74 )
(8) Connecting 144-pin 0.5-mm-pitch Foot Pattern
Figure 3.19 shows how to connect the emulation pod probe to the 144-pin 0.5-mm-pitch foot pattern
on the target system with the M3T-FLX-144NSD (not included), and here following is its procedure.
(1) Attach the NQPACK144SD (NQPACK, hereafter) included with the M3T-FLX-144NSD to
the target system.
(2) Attach the YQPACK144SD (YQPACK, hereafter) included with the M3T-FLX-144NSD to
the NQPACK, matching three holes of the NQPACK and YQPACK.
(3) Insert the included YQ-GUIDE's to the YQPACK.
(4) Attach the FLX160-PRB to the M3T-FLX-144NSD.
(5) Attach the M3T-FLX-144NSD to the YQPACK144SD.
Figure 3.19 Connecting the emulation pod probe and 144-pin 0.5-mm-pitch foot pattern
CAUTION
Notes on Connecting the Target System:
• Take care not to attach the converter board in a wrong direction. It may cause a fatal
damage to the emulation pod.
• The small connectors of the M3T-FLX-144NSD are guaranteed for only 50
insertion/removal iterations.