(7) Connecting 100-pin 0.5-mm-pitch Foot Pattern (Part 3)
Figure 3.18 shows how to connect the emulation pod probe to the 100-pin 0.5-mm-pitch foot pattern
on the target system with the M3T-F160-100NSD (not included), and here following is its procedure.
(1) Attach the NQPACK100SD included with the M3T-F160-100NSD to the target system.
For details on how to attach the M3T-F160-100NSD to the target system, refer to its user's
manual.
(2) Attach the YQPACK100SD included with the M3T-F160-100NSD to the NQPACK100SD.
(3) Insert the included YQ-GUIDE's to the YQPACK100SD.
(4) Attach the FLX160-PRB to the M3T-F160-100NSD.
(5) Attach the M3T-F160-100NSD to the YQPACK100SD.
Figure 3.18 Connecting the emulation pod probe and 100-pin 0.5-mm-pitch foot pattern (part 3)
CAUTION
Notes on Connecting the Target System:
• Take care not to attach the converter board in a wrong direction. It may cause a fatal
damage to the emulation pod.
• The small connectors of the M3T-F160-100NSD are guaranteed for only 50
insertion/removal iterations.