22.3.4
Input Capture Mode (Operating PMC0 and PMC1 Independently)
The input capture mode measures width or period of external pulse. PMC0 and PMC1 can be
measured independently.
Table 22.16
Input Capture Mode Specifications (Independent Operation)
Item
Content
PMC0 Circuit
PMC1 Circuit
Count
sources
Clock sources
One of the following:
•
fC
•
f1
•
Timer B2 underflow
•
Count source of PMC1
One of the following:
•
fC
•
f1
•
Timer B1 underflow
•
Timer B2 underflow
Division
No division, divided-by-8, divided-by-32, or divided-by-64
Count operation
Increment
Measured items
One of the following:
Pulse period (between rising edge and rising edge)
Pulse period (between falling edge and falling edge)
Pulse width (both high level and low level)
Interrupt request generation
timing
•
Timer measurement
•
Counter overflow
Selectable functions
•
Input signal inversion
•
Digital filter